From water to watts
A pump adds energy to water: it lifts it and pushes it through pipes against friction. The power that ends up in the water is the hydraulic power. Because pumps and motors lose energy as heat, the electrical power drawn is higher.
The formulas
- Hydraulic power (W) = ρ × g × Q × H, with ρ = 1,000 kg/m³ × specific gravity, g = 9.80665 m/s², Q in m³/s and H in meters
- Water horsepower = gpm × ft × SG ÷ 3,960
- Motor power = hydraulic power ÷ overall efficiency
- Energy per year = motor power × hours per day × 365
Worked example
A well pump delivers 50 gpm against a total head of 100 ft with an overall efficiency of 70%:
- Water horsepower = 50 × 100 ÷ 3,960 ≈ 1.26 hp, or 943 W hydraulic.
- Motor power = 943 ÷ 0.70 ≈ 1,347 W = 1.81 hp (1.35 kW).
- Running 4 hours a day: 1.347 × 4 × 365 ≈ 1,967 kWh per year.
- At $0.18 per kWh, that costs about $354 per year.
A standard 2 hp motor would be the usual choice.
What counts in total head
Total dynamic head is the sum of:
- Static lift: vertical distance from the water level (in a well, the pumping level, not the static level) to the highest discharge point.
- Friction losses in pipes, elbows, valves and filters, which rise with the square of flow.
- Pressure head needed at the outlet: 1 psi = 2.31 ft of water. A pressure tank set to 50 psi adds about 115 ft.
Typical efficiencies
| Pump type | Overall efficiency |
|---|---|
| Small submersible or jet pump | 30–50% |
| Residential centrifugal pump | 40–60% |
| Commercial centrifugal pump | 60–75% |
| Large industrial pump at best efficiency point | 75–90% |
Specific gravity
Enter 1 for clean water. Use about 1.03 for seawater, 0.7 to 0.9 for many oils and fuels, and up to 1.5 for some slurries. Viscous liquids also reduce pump efficiency, which this simple model does not include.
Saving energy
- Choose a pump whose best efficiency point matches your normal flow and head.
- Avoid throttling with a valve; a variable-speed drive cuts power roughly with the cube of speed.
- Reduce friction with larger pipes and fewer fittings: halving friction head can cut the power more than a premium motor would.
- Oversize the motor by only 10% to 20% over the calculated power.