Storage tank shell thickness calculator: API 650 one-foot method for the bottom course

Enter the tank diameter, liquid level, specific gravity, corrosion allowance and plate stresses to get the API 650 one-foot method design and hydrotest thickness of the bottom course and the next standard plate.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

Value out of range

in

Value out of range

psi

Value out of range

psi

Value out of range

Results

Required first course thickness

0.325 in

Design shell thickness (one-foot method)
0.325 in
Hydrostatic test shell thickness
0.244 in
Next 1/16 in plate thickness
0.3750 in
Hydrostatic pressure at the bottom
17.3 psi

The storage tank shell thickness calculator applies the API 650 one-foot method to give the design thickness, the hydrostatic test thickness and the required thickness of the bottom course of a welded steel tank, with the next standard plate size and the pressure at the bottom.

How the calculation works

  • Enter the diameter of the tank and the maximum liquid level, the specific gravity of the stored liquid and the corrosion allowance.
  • Enter the allowable design stress Sd and the allowable hydrostatic test stress St of the plate material from API 650 (for example 23,200 and 24,900 psi for A36).
  • The calculator applies the API 650 one-foot method: td = 2.6 D (H − 1) G / Sd + CA for the design condition and tt = 2.6 D (H − 1) / St for the hydrostatic test.
  • It gives the required thickness of the first (bottom) course, the next 1/16 in plate and the pressure at the bottom.

Example

A tank of 60 ft diameter holds water (G = 1) to 40 ft. The plate is A36 (Sd = 23,200 psi, St = 24,900 psi) with a corrosion allowance of 0.0625 in. The design thickness is 2.6 × 60 × 39 × 1 / 23,200 + 0.0625 = 0.325 in. The hydrostatic test thickness is 2.6 × 60 × 39 / 24,900 = 0.244 in. The required thickness is 0.325 in, so a 0.375 in plate is used. The pressure at the bottom is 17.3 psi.

Why it matters

The calculator helps tank designers, plant engineers, inspectors and students to make a first estimate of the shell plate thickness, to check an existing tank against a new service or a higher liquid level and to compare plate grades. It also gives the bottom pressure for the design of the foundation.

Good to know

Use the stresses of the plate grade of API 650 and the specific gravity of the heaviest liquid that will be stored. Check the minimum thickness required by the standard for the diameter. Use the full design procedure for the final design. Verify the shell for wind, seismic and vacuum loads, and not only for the liquid.

The hydrostatic pressure calculator gives the pressure from the height of liquid, the tank volume calculator gives the capacity, the pressure vessel stress calculator covers pressurized shells and the density calculator converts the weight of the contents.

Frequently asked questions

What is the one-foot method?

The one-foot method of API 650 computes the thickness of each shell course from the hydrostatic pressure at a point one foot above the bottom of the course. The hoop tension in the shell is the pressure times the radius, so the thickness grows with the diameter and the depth of liquid. The method is allowed for tanks up to 200 ft (60 m) in diameter, and the bottom course is the thickest.

Why are there two thicknesses?

The design thickness is for the stored liquid, with its specific gravity and the corrosion allowance, using the design stress Sd. The hydrostatic test thickness is for the test with water, with a specific gravity of 1 and no corrosion allowance, using the higher test stress St. The required thickness is the larger of the two, and it is also checked against the minimum thickness of the standard for the tank diameter.

What is the corrosion allowance?

It is extra thickness added to the design thickness to account for the loss of metal over the life of the tank. It depends on the liquid and the environment, and the owner specifies it, frequently 1/16 to 1/8 in (1.5 to 3 mm) for steel tanks. The allowance is not included in the hydrostatic test condition, since the test lasts a short time with clean water.

What does the calculator not cover?

The calculator gives the bottom course only. A full tank design also covers the upper courses, the minimum thickness by diameter, the wind and seismic loads, the roof and its supports, the bottom plate, the annular plate, the openings and the foundation. Large tanks above 200 ft diameter need the variable-design-point method, which is a more complex computation. Use it only for a first estimate.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.