Water heater size: how big a tank, or how powerful a tankless unit?

Estimate your peak-hour hot water demand, the first-hour rating and tank size you need, and the power of a tankless heater for the showers you run at once.

Updated on
Your inputs

Value out of range

Value out of range

Value out of range

Value out of range

Value out of range

°F

Value out of range

Results

Suggested tank size

60

Peak-hour demand: minimum first-hour rating
35
Flow for a tankless heater
2
Tankless heater power needed
20.5 kW

Size for your busiest hour

A water heater that is too small runs out during the morning rush; one that is too large wastes energy keeping water hot. For tank heaters, what matters most is not the tank volume itself but the first-hour rating (FHR): how much hot water the heater can deliver in an hour, starting full. It is printed on the EnergyGuide label.

Peak-hour demand

The US Department of Energy suggests adding up the hot water used in your busiest hour:

  • Shower: 10 gallons
  • Bath: 20 gallons
  • Dishwasher: 6 gallons
  • Clothes washer, warm or hot: 7 gallons
  • Food preparation: 5 gallons, hand dishwashing 4 gallons

Choose a heater whose first-hour rating is at least that total.

Example

A family of four takes two showers between 7 and 8 am while the dishwasher runs and breakfast is cooked:

  • Peak-hour demand: 2 × 10 + 6 + 5 + 4 = 35 gallons
  • A typical 40-gallon gas heater has an FHR of 60 to 70 gallons and a 50-gallon electric one about 55 to 65, so either covers it
  • Suggested tank size for four people: about 60 gallons if baths or long showers are common, 50 gallons otherwise

Tankless water heaters

A tankless (on-demand) heater has no stored water, so it is sized by flow rate and temperature rise:

  • Flow = showers running at once × flow per head, for example 1 × 2.0 gpm
  • Temperature rise = target temperature − incoming water temperature, for example 120°F − 50°F = 70°F
  • Power = flow in L/min × rise in °C × 4.186 ÷ 60, here about 20.5 kW

Whole-house electric tankless units often need 25 to 36 kW and several 40 to 60 A breakers; gas units are rated around 150,000 to 199,000 BTU/h. Groundwater is colder in northern states, so the same unit delivers less flow there in winter.

Choosing the type

  • Heat pump water heaters use two to three times less electricity than standard electric tanks, but recover more slowly; choose a slightly larger tank.
  • Gas tanks recover fastest.
  • Tankless saves standby losses and space but costs more to install.

Set the thermostat to about 120°F to limit scalding and standby losses.

Frequently asked questions

What is the first-hour rating?

The amount of hot water a tank water heater can deliver in one hour starting full, shown on the yellow EnergyGuide label. Choose a model whose first-hour rating is at least your peak-hour demand.

How much hot water does a shower use?

The US Department of Energy uses about 10 gallons of hot water per shower for sizing, 20 for a bath, 6 for a dishwasher load and 7 for a warm clothes wash.

How do I size a tankless water heater?

By flow rate and temperature rise: add the flow of fixtures used at once, for example two showers at 2 gpm, and multiply by the rise from the cold water temperature to about 120°F. Electric models need a lot of power; gas models are rated in BTU per hour.

Is a bigger tank always better?

No. A tank that is too large wastes energy keeping unused water hot. A heat pump water heater can save a lot of energy but recovers more slowly, so size it with some extra margin.