What size wood stove do I need?

Enter the heated area, the ceiling height, the insulation, the hours and days of use, the average load, the stove efficiency and the energy in your wood: get the heat output needed and the firewood per season.

Updated on
Your inputs
sq ft

Value out of range

ft

Value out of range

h

Value out of range

Value out of range

%

Value out of range

%

Value out of range

million BTU

Value out of range

Results

Heat output needed

19,200 BTU/h

Do not oversize: a stove run low all the time smolders, dirties the glass and the chimney and burns less cleanly

In kilowatts

5.6 kW

Firewood per season
0.8 cords
Have the stove and flue installed by a qualified pro, sweep the chimney regularly and fit smoke and carbon monoxide alarms

A wood stove that is too small cannot keep up in cold weather, and one that is too big runs smoldering at low output, which wastes wood, clogs the chimney and pollutes more. This calculator estimates the heat output needed from the heated volume and the insulation level, converts it to kilowatts and estimates the firewood you will burn in a season.

How the calculation works

  • Heat needed = area × ceiling height × insulation factor
  • Insulation factor = about 3, 4 or 5 BTU/h per cubic foot for good, average or poor insulation
  • Kilowatts = BTU/h ÷ 3,412
  • Firewood = heat needed × average load × hours × days ÷ (efficiency × energy per cord)

A 600 sq ft area with 8 ft ceilings has 4,800 cubic feet. With average insulation it needs about 19,200 BTU/h, or 5.6 kW. Run 8 hours a day for 150 days at 50% average load, a 75% efficient stove burns about 0.8 cords of seasoned hardwood at 20 million BTU per cord.

Typical stove sizes

Stove output Area heated, roughly
15,000 to 25,000 BTU/h One large room or a small cabin
25,000 to 45,000 BTU/h A medium open-plan home
45,000 to 70,000 BTU/h A large or poorly insulated home

Manufacturers’ heating area claims are often optimistic and assume an open plan. Heat does not travel well through closed doors and hallways.

Why average load matters

A stove rarely runs flat out. In mild weather it might run at a third of its output, in a cold snap near full. The average load setting reflects that; raise it for a cold climate or long burns.

Firewood energy

Seasoned hardwood such as oak, maple or ash holds roughly 20 to 26 million BTU per full cord; softwoods hold less. Wet wood loses much of its energy boiling off water, so burn wood seasoned to below about 20% moisture.

Installation and safety

  • Have the stove and chimney installed by a qualified professional, following the manufacturer’s clearances and local codes; a permit may be required.
  • Sweep the chimney regularly, at least once a year with regular use.
  • Fit smoke alarms and a carbon monoxide alarm.
  • Choose an EPA-certified stove for cleaner, more efficient burning.

Frequently asked questions

What size wood stove for 600 sq ft?

About 19,200 BTU/h, 5.6 kW, with 8 ft ceilings and average insulation.

How much firewood will I burn in a season?

About 0.8 cords running 8 hours a day for 150 days at half load in a 75% efficient stove.

Is a bigger wood stove better?

No; an oversized stove runs smoldering, which wastes wood and dirties the chimney.

How many BTU in a cord of wood?

Roughly 20 to 26 million BTU for seasoned hardwood, less for softwood.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.