The EWMA control chart calculator gives the steady-state limits and the start-up limits of an exponentially weighted moving average chart from the target, the process standard deviation, the weight λ and the width L.
How the calculation works
- Enter the target mean, the process standard deviation and the subgroup size.
- Enter the weight λ and the width L.
- Enter the sample number to get the start-up limits.
- The calculator gives the steady-state limits, the limits at the chosen sample, their relative width and the effective memory.
Example
For a target of 50, a standard deviation of 2 and single measurements, λ = 0.2 and L = 2.86 give a steady-state half-width of 2.86 × 2 × √(0.2 / 1.8) = 1.907, so the limits are 48.093 and 51.907. At sample 3 the limits are 48.362 and 51.638, which is 85.9 % of the steady-state width.
Why it matters
The calculator helps quality engineers, laboratory staff and analysts to set the limits of a chart that detects small drifts of a mean, for example in a filling process, an assay or a service level.
Good to know
Start the plotted value at the target, z(0) = target, and update it with each new sample. If a signal comes, look for a cause of a shift of the mean, then restart the chart. Estimate the standard deviation from the within-subgroup variation or from a moving range, not from the plotted means. The effective memory of about (2 − λ) / λ samples tells you how many recent samples drive the value. An EWMA chart works with individual measurements, which is an advantage when each sample is costly, and it is robust to non-normal data when λ is small. To catch large shifts as well, add a Shewhart chart with 3 sigma limits.
Related tools
The control chart limits calculator sets Shewhart limits, the CUSUM chart calculator is another approach to small shifts, the exponential moving average calculator smooths a series and the p-chart calculator handles proportions.