The capacitive dropper power supply calculator gives the reactance of the dropper capacitor, the current it passes, the DC current and the power at the output, the peak mains voltage and the inrush resistor.
How the calculation works
- Enter the mains voltage and the frequency, then the dropper capacitor in microfarads.
- Enter the DC output voltage of the supply and the inrush current you allow.
- The calculator gives the reactance, the current set by the capacitor, the DC current after a bridge rectifier and the series resistor that limits the inrush.
Example
A 0.47 µF capacitor on 120 V at 60 Hz has a reactance of 5,644 Ω and passes 21.2 mA. After a full-wave bridge this gives 19.1 mA of DC at 5 V, which is 0.096 W. The peak of the mains is 170 V, so an inrush limit of 2 A needs a series resistor of 85 Ω.
Why it matters
The calculator helps electronics designers who need a small, cheap supply for a sensor, a relay, a LED indicator or a timer inside a sealed device, and students who study reactance and AC circuits.
Good to know
A dropper supply has no isolation, so the whole circuit is at mains potential and must be enclosed, insulated and fused. Use a class X2 capacitor with a bleeder resistor of 330 kΩ to 1 MΩ across it, so that the plug is not live when it is unplugged. Add a series resistor, typically 47 to 100 Ω of the flameproof type, to limit the inrush, and a Zener diode that can dissipate the full current when the load is off: at 5 V and 20 mA this is 0.1 W. The output current does not change with the load, so size the capacitor for the highest current you need. Dimmers and noisy mains can add spikes, so protect the circuit with a varistor.
Related tools
The rectifier ripple calculator sizes the reservoir capacitor, the Zener diode calculator sets the series resistor of a shunt regulator, the decoupling capacitor calculator handles the supply of the chip and the RMS voltage calculator converts between rms and peak.