Enter the mains voltage, the frequency, the dropper capacitor and the output voltage to get the reactance, the available current and the power.

Updated on
Your inputs
V

Value out of range

Hz

Value out of range

µF

Value out of range

V

Value out of range

A

Value out of range

Results

DC current after a bridge rectifier

19.1 mA

Reactance of the capacitor
5,644 Ω
Current through the capacitor
21.2 mA
DC power at the output
0.096 W
Peak mains voltage
170 V
Inrush limiting resistor
85 Ω

The capacitive dropper power supply calculator gives the reactance of the dropper capacitor, the current it passes, the DC current and the power at the output, the peak mains voltage and the inrush resistor.

How the calculation works

  • Enter the mains voltage and the frequency, then the dropper capacitor in microfarads.
  • Enter the DC output voltage of the supply and the inrush current you allow.
  • The calculator gives the reactance, the current set by the capacitor, the DC current after a bridge rectifier and the series resistor that limits the inrush.

Example

A 0.47 µF capacitor on 120 V at 60 Hz has a reactance of 5,644 Ω and passes 21.2 mA. After a full-wave bridge this gives 19.1 mA of DC at 5 V, which is 0.096 W. The peak of the mains is 170 V, so an inrush limit of 2 A needs a series resistor of 85 Ω.

Why it matters

The calculator helps electronics designers who need a small, cheap supply for a sensor, a relay, a LED indicator or a timer inside a sealed device, and students who study reactance and AC circuits.

Good to know

A dropper supply has no isolation, so the whole circuit is at mains potential and must be enclosed, insulated and fused. Use a class X2 capacitor with a bleeder resistor of 330 kΩ to 1 MΩ across it, so that the plug is not live when it is unplugged. Add a series resistor, typically 47 to 100 Ω of the flameproof type, to limit the inrush, and a Zener diode that can dissipate the full current when the load is off: at 5 V and 20 mA this is 0.1 W. The output current does not change with the load, so size the capacitor for the highest current you need. Dimmers and noisy mains can add spikes, so protect the circuit with a varistor.

The rectifier ripple calculator sizes the reservoir capacitor, the Zener diode calculator sets the series resistor of a shunt regulator, the decoupling capacitor calculator handles the supply of the chip and the RMS voltage calculator converts between rms and peak.

Frequently asked questions

How does a capacitive dropper work?

A capacitor in series with the mains acts as a lossless impedance, so it limits the current without making heat. The current is I = V / Xc, with Xc = 1 / (2 × π × f × C). A bridge rectifier, a Zener diode and a reservoir capacitor then turn this AC current into a low DC voltage. The circuit is small and cheap but not isolated from the mains.

What current can it supply?

The current is nearly fixed by the capacitor, whatever the load, so it behaves as a current source of about V / Xc. A 0.47 µF capacitor on 120 V and 60 Hz passes about 21 mA, and a 0.33 µF one on 230 V and 50 Hz about 24 mA. The DC current after a full-wave bridge is about 0.9 times the rms current. If the load takes less, the Zener diode absorbs the rest.

What rating must the capacitor have?

Use a capacitor of the X2 safety class, which is made to be connected across the mains and to fail safely. It must be rated for at least the mains voltage in rms, usually 275 VAC for 230 V. The peak voltage is 1.41 times the rms value. A class Y capacitor is meant for a different use, and an ordinary film capacitor is not safe.

Is a capacitive dropper safe?

The circuit is connected to the mains, so every point of it can carry a dangerous voltage. It must be fully enclosed and insulated, with a fuse and a series resistor to limit the inrush when it is plugged at the peak of the wave. It is suitable for a fixed, sealed device such as a small sensor or a LED lamp, never for a prototype on an open bench or for a device that a person can touch.