The octave band to dBA calculator combines eight octave-band levels into the overall A-weighted level, the C-weighted level, the unweighted level and the difference between C and A.
How the calculation works
- Enter the sound level in each octave band from 63 Hz to 8 kHz.
- The calculator adds the standard A and C corrections to each band.
- It converts each weighted level to energy, adds the energies and gives the overall levels, then the C minus A difference.
Example
A spectrum that falls from 62 dB at 63 Hz to 29 dB at 8 kHz, typical of a quiet office with ventilation, gives an overall level of 50.0 dB(A). The C-weighted level is 63.3 dB(C) and the unweighted level 63.9 dB. The difference of 13.4 dB between C and A shows how much of the noise is low frequency.
Why it matters
The calculator helps acoustic consultants, building services engineers, machine designers and safety officers who have octave-band data from a data sheet or a measurement and need the single dB(A) figure used in standards and regulations.
Good to know
A-weighting reduces the low frequencies strongly, so a noise that is loud at 63 and 125 Hz can have a modest dB(A) value and still be heard and felt. Compare the dB(A) and dB(C) values for such noise, and look at the spectrum itself. The calculation uses the corrections at the centre frequency of each octave, which is a good approximation for broadband noise. For legal compliance, such as occupational exposure limits or noise permits, use the measurement made with a class 1 or class 2 sound level meter. Combine several sources with the decibel addition calculator, and remember that the level depends on the distance and the room.
Related tools
The decibel addition calculator adds sound levels, the noise exposure calculator checks the dose at work, the sound insulation calculator gives the reduction of a wall and the speaker SPL calculator gives the level of a loudspeaker.