Skip to content
Omnikalc

Average daylight factor calculator: daylighting of a room with the BRE formula

Enter the room dimensions, the window area, the sky angle, the glass transmittance and the surface reflectance to get the average daylight factor and the illuminance under an overcast sky.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

ft

Value out of range

ft²

Value out of range

°

Value out of range

Value out of range

Value out of range

Results

Average daylight factor

2.51 %

Adequately daylit
Window area as a share of the floor area
19.2 %
Average illuminance under an overcast sky of 929 fc (10,000 lux)
23.3 fc
Total area of the room surfaces
938 ft²

The average daylight factor calculator estimates the daylight in a room from the window area, the glass transmittance, the sky angle and the reflectance of the surfaces with the BRE formula, and gives the illuminance under an overcast sky.

How the calculation works

  • Enter the room length, width and height to get the total area of the room surfaces.
  • Enter the glazed area of the windows, the light transmittance of the glass and the average reflectance of the room surfaces.
  • Enter the vertical angle of sky visible from the center of the window, measured from the horizontal edge of any obstruction such as a facing building.
  • The calculator applies the BRE formula DF = T × Aw × θ / (A × (1 − R²)) and gives the average daylight factor and illuminance.

Example

A room of 16 ft × 13 ft × 9 ft has a total surface area of 2 × (208 + 144 + 117) = 938 ft². It has 40 ft² of glass with a transmittance of 0.68, a sky angle of 65° and an average reflectance of 0.50. The average daylight factor is 0.68 × 40 × 65 / (938 × 0.75) = 2.51%. The windows are 19.2% of the floor area. Under an overcast sky of 929 fc, the average illuminance is about 23.3 fc.

Why it matters

The calculator helps architects, builders, designers and homeowners to check whether a room has enough windows for good daylight, to compare glass types and room finishes and to decide how large a new window should be. It gives a fast first estimate before a daylight simulation.

Good to know

Use light-colored surfaces to increase the reflectance, place the windows high on the wall to bring light deep into the room, and clean the glass. Keep in mind the dirt on the glass and the frame, which can reduce the light by 10 to 30%, and the obstructions. Balance the daylight with the solar heat gain and the glare, and check the building code for the minimum window area.

The illuminance point source calculator covers artificial light, the window area calculator checks the glazing area, the window film calculator covers films that cut glare and heat and the solar elevation angle calculator gives the sun height.

Frequently asked questions

What is the daylight factor?

The daylight factor is the ratio of the illuminance at a point inside a room to the illuminance outdoors under an overcast sky with no direct sun, expressed in percent. A daylight factor of 2% under a design sky of 10,000 lux gives 200 lux inside. It is the standard measure of the daylight quality of a room because the overcast sky is the same worst case in every climate.

What average daylight factor is recommended?

The British standard gives an average daylight factor of at least 2% for a room to appear daylit, with 5% or more giving a well daylit room where electric lighting is rarely needed. Between 2% and 5% electric lighting is often used in the evening and on dark days. For a living room or a kitchen a minimum of 1.5 to 2% is common, and for a bedroom about 1%.

How do I find the sky angle?

The sky angle θ is the angle in degrees measured in a vertical plane from the center of the window to the top of the obstruction in front of it, up to the sky. With no obstruction it is 90°. A building across the street that rises 30° above the horizon from the window gives 60°. The factor is an average, so the center of the window is a good reference point.

What are the limits of the formula?

The formula gives an average over the room and assumes a regular room and an unobstructed window, so it does not show the variation from the window to the back wall, which is large. The daylight is much lower at the back of a deep room. A rule of thumb is that a room is daylit up to about 2 to 2.5 times the window head height. A simulation with software gives the distribution.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.