Skip to content
Omnikalc

Illuminance from a point source calculator: lux and foot-candles at any point of a surface

Enter the luminous intensity of a lamp, its height and the horizontal offset to get the illuminance on a surface in lux and foot-candles, the distance, the angle of incidence and the share of the maximum.

Updated on
Your inputs
cd

Value out of range

ft

Value out of range

ft

Value out of range

Results

Illuminance on the surface (lux)

81.4 lx

Dim: only suitable for circulation
Illuminance on the surface (foot-candles)
7.57 fc
Distance from the lamp
11.66 ft
Angle of incidence
31.0 °
Illuminance directly below the lamp (foot-candles)
12.00 fc
Share of the illuminance directly below
63.1%

The illuminance of a surface lit by a small lamp depends on the intensity of the lamp, on its distance and on the angle at which the light arrives. The point source illuminance calculator gives the lux and the foot-candles at any point, the distance, the angle of incidence and the share of the illuminance directly below.

How the calculation works

  • Enter the luminous intensity of the lamp in the direction of the surface, in candelas. Many lamps give it on the data sheet.
  • Enter the height of the lamp above the surface that you want to light, and the horizontal offset from the point right below the lamp.
  • The calculator finds the distance d = √(h² + x²) and the angle of incidence θ, with cos θ = h / d.
  • It gives the illuminance E = I × cos θ / d² = I × h / d³, in foot-candles and lux, the illuminance directly below the lamp and the share of it that is left at the offset.

Example

A lamp of 1,200 cd hangs 10 ft above a table, and the point you look at is 6 ft to the side. The distance is √(10² + 6²) = 11.66 ft and the angle of incidence is 30.96°. The illuminance is 1,200 × 10 / 11.66³ = 7.57 foot-candles, or 81.4 lux. Right below the lamp it would be 1,200 / 10² = 12.00 foot-candles, so the point receives 63.1 % of that. It is enough to move around but too dim for detailed work.

Why it matters

The calculator helps lighting designers, photographers, growers and students to place a spotlight, a downlight or a work lamp, and to check if a point of a table or a floor gets enough light. It shows how fast the light falls when you move away from the axis of the lamp.

Good to know

The formula is valid for a small lamp compared with the distance, such as a bulb, an LED or a spotlight, and for the direct light only. Reflections from walls and ceiling add to the result in a room. If the intensity changes with the direction, use the value in the direction of the point, given on the photometric diagram of the lamp. A light meter is the best way to check the result.

The lumens calculator sizes the total light of a room, the inverse square law calculator shows how intensity falls with distance, the recessed lighting calculator spaces the downlights, and the daily light integral calculator measures light for plants.

Frequently asked questions

What is illuminance?

Illuminance is the amount of light that falls on a surface. It is measured in lux, which is one lumen per square meter, or in foot-candles, which is one lumen per square foot. One foot-candle is 10.764 lux. It is the quantity that lighting standards give for rooms and workplaces.

What is the cosine law of illuminance?

A beam that hits a surface at an angle spreads over a larger area, so the surface receives less light. The illuminance is divided by the cosine of the angle between the direction of the light and the line perpendicular to the surface. Together with the inverse square law, it gives E = I × cos θ / d².

Why is candela used and not lumen?

A lumen is the total light output of a source in all directions. The candela is the intensity in one direction, which is what you need to compute the light on a given point. For a lamp that spreads light evenly in a cone, the intensity in candelas is about the lumens divided by the solid angle of the cone.

How much light do I need?

Typical levels are 50 to 100 lux for corridors, 150 to 300 lux for living areas, 300 to 500 lux for reading and desk work, and 750 lux or more for fine work. The calculator gives the light from one lamp only, so add the contribution of other lamps and of the reflections from walls and ceiling.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.