Skip to content
Omnikalc

Combined footing calculator: size a footing so that the resultant of two column loads falls at its centroid

Enter the loads of the two columns, their spacing, the distance of column 1 to the end of the footing and the allowable soil pressure to get the resultant, the length, the width, the load per foot and the maximum moment.

Updated on
Your inputs
kips

Value out of range

kips

Value out of range

ft

Value out of range

ft

Value out of range

ksf

Value out of range

Results

Width of the footing

5.90 ft

Resultant of the loads from column 1
9.60 ft
Length of the footing
21.20 ft
Load per foot of length
23.58 kips/ft
Maximum moment between the columns
648 kip-ft

The combined footing calculator gives the length, the width and the maximum moment of a rectangular footing under two columns, placed so that the resultant of the loads falls at its centroid, from the allowable soil pressure.

How the calculation works

  • Enter the loads of the two columns and their spacing, with column 1 being the one at the edge of the footing (for example at a property line).
  • Enter the distance from column 1 to the end of the footing and the allowable soil pressure.
  • The calculator places the footing so that the resultant of the loads is at its centroid, which gives a uniform soil pressure, and finds the length, the width, the load per foot and the maximum moment between the columns.

Example

Column 1 carries 200 kips and column 2 300 kips, 16 ft apart, with column 1 at 1 ft from the end, on a soil of 4 ksf. The resultant is at 300 × 16 / 500 = 9.60 ft from column 1. The footing length is 2 × (1 + 9.60) = 21.20 ft and its width is 500 / (4 × 21.20) = 5.90 ft. The load per foot is 500 / 21.20 = 23.58 kips/ft, and the shear is zero at 200 / 23.58 = 8.48 ft from the end, where the moment is 648 kip-ft.

Why it matters

The calculator helps structural engineers, foundation designers, contractors and students to size a footing for a column at a property line, to compare the dimensions with a strap footing and to prepare the design of the reinforcement. It saves the time of the first sizing and shows how the loads and the spacing change the footing.

Good to know

Use the service loads for the soil pressure and the factored loads for the reinforced concrete design. Round the dimensions up to a practical value and recompute the pressure. Check the one-way and punching shear, and place the longitudinal reinforcement at the top between the columns and at the bottom under them.

The footing size calculator sizes a simple footing, the bearing capacity calculator gives the allowable soil pressure, the concrete volume calculator gives the quantity of concrete and the rebar development length calculator covers the anchorage of the bars.

Frequently asked questions

What is a combined footing?

A combined footing is a single footing that supports two or more columns. It is used when a column is so close to a property line that an individual footing would extend beyond it, or when the columns are so close that the individual footings would overlap. Placing the columns on a single rectangular footing, centered under the resultant of their loads, gives a uniform pressure on the soil and avoids the rotation of an eccentric footing.

How is the length of the footing found?

For a uniform pressure, the resultant of the column loads must pass through the centroid of the footing. The resultant is at x = P2 s / (P1 + P2) from column 1, so the footing extends this distance plus the distance of column 1 to the end on each side of the centroid, which gives L = 2 (e + x). The width follows from the total load, the length and the allowable pressure: B = (P1 + P2) / (qa L).

How is the moment computed?

The footing is a beam loaded upward by the soil, with a uniform load of (P1 + P2) / L per unit length, and downward by the two columns. The shear changes sign between the columns, and the moment is maximum, with a negative (hogging) sign, where the shear is zero. The calculator gives the value, which is used to design the top reinforcement of the footing in the longitudinal direction.

What are the limits of the calculator?

The calculator uses service loads for the size of the footing and a linear distribution of the pressure, with a rigid footing. It does not check punching shear, one-way shear, the transverse bending under the columns, the settlement, or the bearing under the factored loads for the reinforced concrete design. A qualified structural engineer must design the footing and its reinforcement.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.