Skip to content
Omnikalc

Concrete pump pressure calculator: pressure needed to push concrete through a pipeline

Enter the length, the rise, the pipe diameter, the slump, the rate and the bends to get the velocity, the friction loss, the pump pressure required and the ratio to the pump rating.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

in

Value out of range

yd³/h

Value out of range

Value out of range

psi

Value out of range

Results

Pump pressure required

558 psi

Velocity in the pipe
3.3 ft/s
Friction loss per foot of pipe
0.82 psi/ft
Ratio to the pump rating
0.46
Within the rating of the pump

The concrete pump pressure calculator gives the velocity, the friction loss, the pump pressure required and the ratio to the pump rating for a concrete line, from the length, the rise, the diameter of the pipe, the bends, the slump and the pumping rate.

How the calculation works

  • Enter the horizontal length and the vertical rise of the pipeline, choose the inside diameter and enter the number of 90° bends.
  • Enter the slump of the concrete, the pumping rate and the maximum pressure of the pump from its data sheet.
  • The calculator finds the velocity in the pipe, the friction loss per foot, the pump pressure required and the ratio to the rating of the pump.

Example

A line has 500 ft of horizontal pipe, 4 bends of 90° (each equal to 13 ft of straight pipe, so 552 ft in all) and a rise of 100 ft. The pipe is 5 in in diameter, the slump is 4 in and the rate is 60 yd³/h, so the velocity is 3.3 ft/s. The friction loss is 0.82 psi/ft, or about 453.5 psi over 552 ft. The head of 100 ft of concrete adds about 104.1 psi, so the pump pressure required is 558 psi. For a pump rated at 1,200 psi, the ratio is 0.46.

Why it matters

The calculator helps concrete contractors, pump operators, site engineers and students to check that a pump can reach a high floor or a long distance, to choose the pipe diameter and the pumping rate, and to see how the slump and the bends change the pressure.

Good to know

Use a pipe diameter that keeps the velocity between about 2 and 5 ft/s, keep the line as straight and short as possible, and prime the line with a grout before the first load. Use a mix designed for pumping with enough fines and a good plasticizer, and stay under about 80 % of the rated pressure of the pump. Clamp and support the pipeline well, because the pressure pulses can move the pipes and injure the workers near the line.

The concrete volume calculator gives the quantity to order, the concrete formwork calculator checks the pressure on the forms, the pipe flow velocity calculator relates the flow and the pipe size and the pump power calculator gives the power needed to move a fluid.

Frequently asked questions

How is the pressure of a concrete pump estimated?

The pressure is the sum of the friction in the pipe and the static head. The friction depends on the pipe radius, the velocity and two constants of the concrete, one for the yield resistance and one for the viscosity, which decrease when the slump increases. The static head is the unit weight of the concrete, about 150 pcf, times the height of the rise. The calculator multiplies the friction loss per foot by the equivalent length of the line.

How are the bends counted?

A 90° bend causes more resistance than a straight pipe, and the calculator counts each bend as 13 ft (4 m) of straight pipe. A tight bend or a bend of a small radius can be worth much more, and a flexible end hose adds resistance too. Use fewer bends, with a large radius, and keep the hose short to lower the pressure.

Why does the slump matter so much?

A stiffer mix has a higher yield resistance and a higher viscosity, so the pressure grows quickly when the slump is low or when the mix has a low paste content. A slump of 4 to 6 in is typical for pumping, and the use of a plasticizer is the best way to lower the pressure without more water. A mix that bleeds or segregates under the pressure can block the line.

What are the limits of the calculator?

The calculator is an empirical estimate for a normal-weight mix in a steel pipe at a steady rate. It does not include the reducers, the tapered sections, the start-up with a dry pipe, the lubrication of the line, the age of the mix or the effect of the temperature. Check the result with the pump supplier and with a trial, and keep a margin on the rated pressure.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.