A cyclone removes dust from a gas by centrifugal force. The cyclone cut size calculator applies Lapple’s model to give the cut size d50, the collection efficiency at a chosen particle size and the particle size that is collected at 90%.
How the calculation works
- Enter the inlet width of the cyclone, the effective number of turns of the gas in the body (5 to 6 for a standard high-efficiency cyclone), and the inlet gas velocity (50 to 70 ft/s).
- Enter the densities of the particles and of the gas, the viscosity of the gas, and the particle size that you want to check.
- The calculator applies Lapple’s cut size d50 = √[9 µ W / (2π Ne Vi (ρp − ρg))], the size of the particles that are collected with 50% efficiency.
- It gives the collection efficiency at your particle size with Lapple’s curve η = 1 / [1 + (d50 / d)²], and the size collected at 90%.
Example
A cyclone has an inlet width of 0.5 ft, 5 effective turns and an inlet velocity of 50 ft/s. The dust has a density of 150 lb/ft³ and the gas (air at 0.075 lb/ft³ and 0.0185 cP) is hot. The cut size is d50 = √[9 × 1.243×10⁻⁵ × 0.5 / (2π × 5 × 50 × 149.9)] = 4.70 µm. For 10 µm particles, the collection efficiency is 1 / (1 + (4.70 / 10)²) = 81.9%. Particles of 14.1 µm (3 × d50) are collected at 90%.
Why it matters
The calculator helps air pollution control engineers, plant managers, woodworking and grain facility designers, and students to see which particles a cyclone collects, to compare designs, and to decide whether a fine filter is needed downstream. It supports the pre-cleaning step before a baghouse.
Good to know
Use the gas viscosity at the working temperature, which rises with the temperature. Increase the inlet velocity to improve the collection, but keep it below the limit at which the particles are re-entrained (about 80 ft/s). Use the particle size distribution of the real dust. Compute the pressure drop to size the fan.
Related tools
The Stokes’ law calculator gives the settling velocity of a particle, the terminal velocity calculator covers falling objects, the Reynolds number calculator checks the flow regime and the centrifuge RCF calculator covers centrifugal separation.