Hydrostatic test pressure calculator: test pressure of a pipe or a pressure vessel

Enter the design pressure, the code factor and the allowable stresses at the test and design temperatures to get the stress ratio, the hydrostatic test pressure and the energy stored in the test water.

Updated on
Your inputs
psig

Value out of range

psi

Value out of range

psi

Value out of range

ft³

Value out of range

Results

Hydrostatic test pressure

545 psig

Stress ratio (test over design temperature)
1.212
Test pressure as a share of the design pressure
182 %
Energy stored in the compressed water
714 ft·lbf

The hydrostatic test pressure calculator gives the test pressure of a pipe or a pressure vessel from the design pressure, the code factor (B31.3, ASME VIII or EN 13445) and the stress ratio at the test and design temperatures, with the energy stored in the water.

How the calculation works

  • Enter the design pressure of the piping or vessel and choose the test pressure factor of the applicable code (1.5 for B31.3, 1.3 for ASME VIII-1, 1.43 for EN 13445).
  • Enter the allowable stress of the material at the test temperature and at the design temperature (from the code stress tables).
  • The calculator multiplies the design pressure by the code factor and by the stress ratio St / S, which is limited to 6.5 as in ASME B31.3.
  • It gives the test pressure and, for safety, the energy stored in the compressed water for the volume of the system.

Example

A process line has a design pressure of 300 psig. At the design temperature the allowable stress is 16,500 psi, and at the test temperature it is 20,000 psi, so the stress ratio is 1.212. With the B31.3 factor of 1.5, the hydrostatic test pressure is 1.5 × 300 × 1.212 = 545 psig, or 182% of the design pressure. For 10 ft³ of water, the energy stored is 545² × 17,280 / (2 × 300,000) / 12 = 714 ft·lbf.

Why it matters

The calculator helps piping and pressure vessel engineers, inspectors, commissioning teams and students to compute the test pressure quickly, to plan a pressure test and to understand the safety side. It gives the pressure for the test procedure and the gauge range to be used for the test.

Good to know

Always confirm the factor and the stress values with the code edition of your project. Use the lowest allowable stress ratio among the components of the system. Choose a gauge with a range of about twice the test pressure. Do the test at a temperature above the minimum metal temperature, and keep people away from the system during the pressurization.

The pipe wall thickness calculator gives the design thickness, the pressure vessel stress calculator checks the hoop stress, the hydrostatic pressure calculator gives the pressure from the water height and the pressure tank calculator covers the air volume.

Frequently asked questions

How is the hydrostatic test pressure defined?

The test pressure is the design pressure times a code factor times the ratio of the allowable stress at the test temperature to the allowable stress at the design temperature. The ratio reflects that a system that works hot has a lower allowable stress than at room temperature, so the test at room temperature must be raised to give the same stress margin. ASME B31.3 limits the ratio to 6.5 for materials that lose strength a lot.

Which factor applies to my system?

ASME B31.3 requires 1.5 times the design pressure for process piping. ASME VIII Division 1 requires 1.3 times the maximum allowable working pressure for vessels built since 1999, and 1.5 for older editions. European standard EN 13445 and the Pressure Equipment Directive use 1.43 times the design pressure, or the pressure with a stress ratio, whichever is higher. Always follow the code that your equipment is built to.

Why is the stored energy useful?

Water is nearly incompressible, so a water test stores little energy compared with a pneumatic test with air. The calculator shows this energy so that you can see the difference. A pneumatic test at the same pressure stores thousands of times more energy and can release a deadly blast, so it should be limited to systems that cannot take water and be done with a special procedure.

What must I check before the test?

Check the temperature of the test water, which must be above the minimum design metal temperature to avoid brittle fracture. Vent all air from the system, since trapped air stores energy and slows the pressure rise. Isolate or remove the parts that cannot see the test pressure, such as instruments and relief valves. Hold the pressure long enough for inspection, usually at least 10 minutes, and relieve it slowly.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.