Peltier cooler calculator: how much heat a thermoelectric module pumps

Enter the Seebeck coefficient, the resistance, the thermal conductance, the current and the side temperatures of a thermoelectric module to get the cooling power, the electrical input, the COP, the heat rejected and the current for the maximum cooling.

Updated on
Your inputs
V/K

Value out of range

A

Value out of range

Ω

Value out of range

W/K

Value out of range

°C

Value out of range

°C

Value out of range

Results

Heat pumped from the cold side Qc

18.47 W

The module pumps heat from the cold side
Electrical power input
22.50 W
Coefficient of performance Qc / P
0.821
Heat rejected at the hot side
40.97 W
Current for the maximum cooling
7.08 A

A Peltier module pumps heat from one face to the other when a current flows. The Peltier cooler calculator finds the cooling power, the electrical input, the COP, the heat rejected at the hot side and the current for the maximum cooling from the module parameters and the temperatures.

How the calculation works

  • Enter the Seebeck coefficient α, the electrical resistance R and the thermal conductance K of the thermoelectric module, from its data sheet (a module of 127 couples has α of about 0.05 V/K, R of 1 to 2 Ω and K of 0.5 W/K).
  • Enter the current and the temperatures of the hot and the cold sides.
  • The calculator applies the standard model of a Peltier module: Qc = α I Tc − ½ I² R − K ΔT, the Peltier cooling minus half of the Joule heat minus the heat conducted back from the hot side.
  • It computes the electrical power P = α I ΔT + I² R, the COP = Qc / P, the heat rejected Qh = Qc + P and the current that maximizes the cooling, Iopt = α Tc / R.

Example

A module with α = 0.05 V/K, R = 2 Ω and K = 0.5 W/K runs at 3 A, with a hot side at 40 °C and a cold side at 10 °C (283.15 K). The Peltier cooling is 0.05 × 3 × 283.15 = 42.47 W, the Joule heat takes half of 3² × 2 = 9.0 W and the conduction is 0.5 × 30 = 15.0 W, so Qc = 18.47 W. The electrical power is 0.05 × 3 × 30 + 18 = 22.50 W, the COP is 0.821, the hot side rejects 40.97 W and the current for maximum cooling is 7.08 A.

Why it matters

The calculator helps electronics designers, makers, makers of mini fridges, camera and laser coolers, and students to estimate whether a thermoelectric module can cool a load, to size the power supply and the heat sink on the hot side, and to compare the options. It shows the compromise between the cooling and the efficiency.

Good to know

Size the heat sink for the heat rejected on the hot side, which is the cooling plus the electrical power. Do not run above the optimum current: the cooling falls and the heat increases. Use a thermal grease or a pad on both faces. Keep the temperature difference as small as possible to keep a useful COP.

The heat sink calculator sizes the hot-side cooler, the Joule heating calculator gives the heat in the resistance, the Carnot efficiency calculator gives the ideal limit and Ohm’s law calculator gives the supply voltage.

Frequently asked questions

How does a Peltier module cool?

A thermoelectric (Peltier) module is made of many pairs of semiconductor pillars connected electrically in series and thermally in parallel. When a current passes, it carries heat from one face to the other: the cold side absorbs heat and the hot side rejects it. There are no moving parts and no refrigerant, so the module is silent and compact, and it can be reversed to heat. Its efficiency is low compared with a compressor.

What are the three terms of the cooling power?

The heat pumped by the Peltier effect, α I Tc, grows with the current. The Joule heat I² R is generated inside the module, and half of it goes to the cold side. The heat conducted back through the pillars, K ΔT, grows with the temperature difference. At a low current the Peltier term dominates, at a high current the Joule heat does, so there is an optimum current Iopt = α Tc / R.

Why is the COP so low?

The module has to pump the heat against a temperature difference, and its own Joule heating and conduction waste a large part of the effort. The COP is typically 0.3 to 1 with a temperature difference of 20 to 40 degrees, against 3 to 5 for a compressor. It increases a lot at a small temperature difference and a low current, and it falls to zero at the maximum temperature difference of the module, about 65 to 70 degrees.

What are the limits of this calculator?

The model uses constant parameters α, R and K, which actually change with the temperature. The data sheet of the module gives them at one temperature, which is often 27 °C. The hot side must be cooled by a heat sink and a fan, because the hot side temperature rises with the heat to reject, and this lowers the cooling. The calculator ignores the thermal resistance of the interfaces and the heat load of the environment.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.