A Peltier module pumps heat from one face to the other when a current flows. The Peltier cooler calculator finds the cooling power, the electrical input, the COP, the heat rejected at the hot side and the current for the maximum cooling from the module parameters and the temperatures.
How the calculation works
- Enter the Seebeck coefficient α, the electrical resistance R and the thermal conductance K of the thermoelectric module, from its data sheet (a module of 127 couples has α of about 0.05 V/K, R of 1 to 2 Ω and K of 0.5 W/K).
- Enter the current and the temperatures of the hot and the cold sides.
- The calculator applies the standard model of a Peltier module: Qc = α I Tc − ½ I² R − K ΔT, the Peltier cooling minus half of the Joule heat minus the heat conducted back from the hot side.
- It computes the electrical power P = α I ΔT + I² R, the COP = Qc / P, the heat rejected Qh = Qc + P and the current that maximizes the cooling, Iopt = α Tc / R.
Example
A module with α = 0.05 V/K, R = 2 Ω and K = 0.5 W/K runs at 3 A, with a hot side at 40 °C and a cold side at 10 °C (283.15 K). The Peltier cooling is 0.05 × 3 × 283.15 = 42.47 W, the Joule heat takes half of 3² × 2 = 9.0 W and the conduction is 0.5 × 30 = 15.0 W, so Qc = 18.47 W. The electrical power is 0.05 × 3 × 30 + 18 = 22.50 W, the COP is 0.821, the hot side rejects 40.97 W and the current for maximum cooling is 7.08 A.
Why it matters
The calculator helps electronics designers, makers, makers of mini fridges, camera and laser coolers, and students to estimate whether a thermoelectric module can cool a load, to size the power supply and the heat sink on the hot side, and to compare the options. It shows the compromise between the cooling and the efficiency.
Good to know
Size the heat sink for the heat rejected on the hot side, which is the cooling plus the electrical power. Do not run above the optimum current: the cooling falls and the heat increases. Use a thermal grease or a pad on both faces. Keep the temperature difference as small as possible to keep a useful COP.
Related tools
The heat sink calculator sizes the hot-side cooler, the Joule heating calculator gives the heat in the resistance, the Carnot efficiency calculator gives the ideal limit and Ohm’s law calculator gives the supply voltage.