A tuned mass damper is a small mass on a spring that absorbs the vibration of a tall building, a bridge or a floor. The tuned mass damper calculator applies the Den Hartog equations to give the damper mass, its optimal frequency, its damping ratio, the spring stiffness, the damping coefficient and the equivalent damping of the structure.
How the calculation works
- Enter the modal mass of the structure for the mode to damp (the generalized mass of the first mode, often 25% to 50% of the total mass of a tall building) and its natural frequency.
- Enter the mass ratio μ of the damper to the structure. Typical values are 0.5% to 5%, and a higher ratio gives a better and more robust damping.
- The calculator applies the optimal parameters of Den Hartog for an undamped structure under a harmonic force: fopt = fs / (1 + μ) and ζopt = √(3μ / (8(1 + μ)³)).
- It then gives the spring stiffness k = m ω² and the damping coefficient c = 2 ζ m ω of the damper, the peak amplification √(1 + 2/μ) and the equivalent damping ratio of the structure.
Example
A structure with a modal mass of 500,000 lb and a frequency of 1.00 Hz gets a damper with a mass ratio of 2%. The damper mass is 10,000 lb. The optimal frequency is 1.00 / 1.02 = 0.9804 Hz, and the optimal damping ratio is √(3 × 0.02 / (8 × 1.02³)) = 8.41%. With the mass 10,000 / 386.4 = 25.88 lb·s²/in and ω = 6.160 rad/s, the spring stiffness is 982 lb/in and the damping coefficient is 26.8 lb·s/in. The peak amplification falls to √(1 + 2/0.02) = 10.05, which is an equivalent damping of 4.98%.
Why it matters
The calculator helps structural and mechanical engineering students and designers to understand how a damper is tuned, to estimate its size for a given mass ratio and to see how much the vibration can fall. It gives the starting values for a detailed design.
Good to know
Use the modal mass of the mode to control, not the total mass. Check the stroke of the damper: it can be several times larger than the motion of the structure. Plan for the adjustment of the spring, since the frequency of the structure is uncertain and can change with time. Include the real structural damping in the final analysis.
Related tools
The pendulum calculator gives the frequency of a pendulum damper, the wind load calculator estimates the excitation of a tall structure, the compression spring calculator sizes the spring and the earthquake magnitude calculator covers seismic events.