VPD: is the air too dry or too humid for your plants?

Compute the air and leaf vapor pressure deficit from temperature and relative humidity, and compare it with the usual ranges for greenhouses and grow rooms.

Updated on
Your inputs
°F

Value out of range

%

Value out of range

°F

Value out of range

Results

Leaf VPD

0.87 kPa

0.8 to 1.2 kPa: the sweet spot for vegetative growth
Air VPD
1.27 kPa
Saturation vapor pressure of the air
3.17 kPa
Actual vapor pressure
1.90 kPa

What VPD measures

The vapor pressure deficit (VPD) is the difference between the amount of water vapor the air could hold when saturated and the amount it actually holds. Unlike relative humidity, it tells you directly how strongly the air pulls water out of leaves. Growers use it to manage transpiration, nutrient uptake and disease risk in greenhouses and grow rooms.

Formula

The saturation vapor pressure, in kilopascals, is estimated with the Tetens equation:

SVP = 0.6108 × e^(17.27 × T ÷ (T + 237.3)), with T in °C

  • Actual vapor pressure: AVP = SVP(air) × RH ÷ 100.
  • Air VPD = SVP(air) − AVP.
  • Leaf VPD = SVP(leaf) − AVP, using the leaf temperature.

Leaves are often slightly cooler than the air because transpiration cools them, so the leaf VPD is usually a little lower than the air VPD. Under high-intensity lamps, leaves can instead be warmer than the air.

Example

At 77 °F (25 °C) and 60% relative humidity, SVP ≈ 3.17 kPa and AVP ≈ 1.90 kPa, so the air VPD is about 1.27 kPa. With leaves 4 °F cooler, the leaf VPD is about 0.87 kPa.

Target ranges

Leaf VPD Situation
under 0.4 kPa too humid: mold, mildew and weak roots
0.4 to 0.8 kPa seedlings, cuttings and clones
0.8 to 1.2 kPa vegetative growth
1.2 to 1.6 kPa flowering and fruiting
over 1.6 kPa dry air: stomata close, growth slows and plants may wilt

These are general ranges; tropical foliage plants prefer the lower end and many fruiting crops tolerate higher values.

How to adjust VPD

  • VPD too high: raise humidity with a humidifier or misting, lower the temperature, or reduce ventilation with dry outside air.
  • VPD too low: run a dehumidifier, raise the temperature slightly, improve air circulation and avoid watering late in the day.

Measuring tips

Place the thermometer and hygrometer at canopy height, shaded from lamps. An infrared thermometer pointed at the leaves gives the leaf temperature. Check VPD at both the start and the end of the light period, when humidity often changes the most.

Frequently asked questions

What is a good VPD for plants?

Roughly 0.4 to 0.8 kPa for seedlings and clones, 0.8 to 1.2 kPa for vegetative growth and 1.2 to 1.6 kPa for flowering.

How do you calculate VPD?

VPD = saturation vapor pressure × (1 − RH ÷ 100). At 77 °F and 60% humidity, the air VPD is about 1.27 kPa.

What is the difference between air VPD and leaf VPD?

Leaf VPD uses the leaf temperature, usually a little cooler than the air, so it is often slightly lower than air VPD.

How do I lower a high VPD?

Raise the humidity, lower the temperature or reduce ventilation with dry air.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.