Cardiac output, cardiac index and systemic vascular resistance

Calculate cardiac output from heart rate and stroke volume, the cardiac index adjusted for body surface area and the systemic vascular resistance.

Updated on
Your inputs
bpm

Value out of range

mL

Value out of range

Value out of range

Value out of range

mmHg

Value out of range

mmHg

Value out of range

Results

Cardiac output

5.25 L/min

Within the usual resting range of about 4–8 L/min

Cardiac index

2.61 L/min/m²

2.5–4.0: usual range
Stroke volume index
34.9 mL/m²
Systemic vascular resistance
1,143 dyn·s/cm⁵
800–1,200: usual range
Body surface area (Mosteller)
2.01 m²

What cardiac output measures

Cardiac output is the volume of blood the heart pumps each minute. It is the product of how often the heart beats and how much it ejects with each beat:

cardiac output (L/min) = heart rate × stroke volume ÷ 1,000

At rest, a healthy adult’s cardiac output is about 4 to 8 L/min. During hard exercise, it can rise to 20 L/min or more in trained athletes.

Adjusting for body size

A large person needs more blood flow than a small one, so clinicians use the cardiac index, cardiac output divided by body surface area (BSA). The calculator estimates BSA with the Mosteller formula, √(height in cm × weight in kg ÷ 3,600).

Measure Usual resting range
Cardiac output 4 to 8 L/min
Cardiac index 2.5 to 4.0 L/min/m²
Stroke volume 60 to 100 mL
Stroke volume index 33 to 47 mL/m²
Systemic vascular resistance 800 to 1,200 dyn·s/cm⁵

Systemic vascular resistance

The resistance the left ventricle pumps against is:

SVR = 80 × (MAP − CVP) ÷ cardiac output

where MAP is the mean arterial pressure and CVP the central venous pressure. The factor 80 converts mmHg·min/L into dyn·s/cm⁵.

Worked example

A heart rate of 75, stroke volume of 70 mL, a patient 5 ft 10 in and 180 lb, MAP 80 and CVP 5 mmHg:

Result Value
Cardiac output 5.25 L/min
Body surface area 2.01 m²
Cardiac index 2.61 L/min/m²
Stroke volume index 34.9 mL/m²
Systemic vascular resistance 1,143 dyn·s/cm⁵

All values are in the usual range.

Interpreting patterns

  • Low cardiac index with high SVR: the pattern of cardiogenic or hypovolemic shock, with the vessels clamping down.
  • High cardiac index with low SVR: the typical picture of early septic shock or other vasodilated states.
  • A cardiac index below 2.2 L/min/m² with signs of poor perfusion and pulmonary congestion is part of the definition of cardiogenic shock.

How the numbers are obtained

Stroke volume can be measured by echocardiography, by thermodilution with a pulmonary artery catheter, or estimated by monitors that analyze the arterial pressure waveform. Each method has its own error, and trends over time are often more useful than a single value.

This calculator is for general information and education. It is not medical advice and does not replace the judgment of a doctor, nurse or pharmacist who knows the full clinical picture.

Frequently asked questions

How is cardiac output calculated?

Cardiac output = heart rate × stroke volume. At 75 beats per minute and 70 mL per beat, it is 5.25 L/min.

What is the cardiac index?

Cardiac output divided by body surface area, so that people of different sizes can be compared. A normal resting value is about 2.5 to 4 L/min/m².

How is systemic vascular resistance calculated?

SVR = 80 × (mean arterial pressure − central venous pressure) ÷ cardiac output, in dyn·s/cm⁵. The usual range is about 800 to 1,200.

How is stroke volume measured?

By echocardiography, a pulmonary artery catheter (thermodilution) or minimally invasive monitors that analyze the arterial pressure waveform. This calculator uses the value you enter.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.