The Dixon Q test calculator tells you whether a suspect value is an outlier in a small sample of 3 to 10 measurements, from the Q statistic and its critical value at 90, 95 or 99 % confidence.
How the calculation works
- Enter the suspect value, its nearest neighbor and the value at the other end of the sorted data.
- Enter the number of measurements and the confidence level.
- The calculator gives Q, the critical value, the verdict, the gap, the range and the margin.
Example
Five titrations give 10.12, 10.15, 10.18, 10.21 and 10.52 mL. The suspect value is 10.52, its nearest neighbor is 10.21 and the other end is 10.12. The gap is 0.3100 and the range 0.4000, so Q = 0.3100 / 0.4000 = 0.7750. At 95 % with 5 measurements, the critical value is 0.710. Q is above it by 0.0650, so the value is an outlier and can be rejected.
Why it matters
The calculator helps chemistry and biology students, laboratory technicians who run replicate measurements, and quality analysts who must decide whether to keep a doubtful result.
Good to know
Sort the data first, then test the largest value with the gap to the second largest, or the smallest with the gap to the second smallest. The test is meant for data that are otherwise normally distributed. It has low power with three measurements, where only an extreme value is detected, so it is better to collect a few more. Never reject a value only because it looks odd: look for a cause such as a spill, a misread burette or a calculation slip, and document the decision. The critical values come from the standard published table for the single-gap form of the test. For larger samples, the Grubbs test is preferred.
Related tools
The Grubbs test calculator handles larger samples, the outlier calculator uses the interquartile range, the average calculator gives the mean and median and the limit of detection calculator covers the lowest measurable level.