Activated sludge calculator: F/M ratio, sludge age and retention time

Enter the plant flow, the tank volume, the BOD, the MLVSS and the wasting data to get the F/M ratio, the hydraulic retention time, the sludge age (SRT), the BOD load and the waste solids.

Updated on
Your inputs

Value out of range

Value out of range

mg/L

Value out of range

mg/L

Value out of range

Value out of range

mg/L

Value out of range

mg/L

Value out of range

Results

Food to microorganism ratio (F/M)

0.20 per day

Conventional range

Solids retention time (sludge age)

10.5 days

Typical for BOD removal and nitrification
Hydraulic retention time
9.6 hours
BOD load
1,669 lb/day
Waste solids per day
668 lb/day

The activated sludge process uses a mass of microorganisms to remove organic matter from wastewater. To keep it stable, operators track three numbers: the F/M ratio, the hydraulic retention time and the sludge age. This activated sludge calculator takes the plant flow, the tank volume, the influent BOD, the MLVSS, the waste sludge flow and concentration and the effluent solids to give them, with the BOD load and waste solids.

How the calculation works

  • F/M ratio = flow × influent BOD ÷ (tank volume × MLVSS). It is the pounds of BOD fed each day per pound of microorganisms (volatile solids) in the tank.
  • Hydraulic retention time (HRT) = tank volume ÷ flow × 24 hours.
  • Solids retention time (SRT), or sludge age = solids in the tank ÷ solids leaving per day, which is the wasted sludge plus the solids in the effluent: V × X ÷ (Qw × Xw + (Q − Qw) × Xe).
  • BOD load = flow × BOD, and waste solids = waste flow × waste concentration, each shown in pounds per day.

Example

A plant treats 1 MGD (3,785 m³/d) of wastewater with a BOD of 200 mg/L in a 0.4 Mgal tank at 2,500 mg/L MLVSS. The F/M ratio is 0.20 per day and the HRT is 9.6 hours. It wastes 0.01 MGD of sludge at 8,000 mg/L, and the effluent holds 15 mg/L of solids. The SRT is 3,785,400 ÷ 359,045 = 10.5 days.

Why it matters

Operators of municipal and industrial plants use these numbers every day to decide how much sludge to waste, and students use them in wastewater courses. A sludge age that is too short washes out the nitrifiers, and one that is too long leads to old sludge, foam and poor settling. The calculation shows the effect of changing the wasting rate.

Good to know

The sludge age formula here uses MLVSS in the numerator and the waste concentration in the same basis, and the common practice is to use MLSS and total suspended solids throughout, so be consistent. It assumes steady-state operation and ignores solids in the clarifier, which can add to the sludge inventory. Typical ranges depend on the process type, the temperature and the local permit. This tool is for training and checks and does not replace the plant’s operating procedures or a process design by an engineer.

The COD calculator measures the strength of the wastewater, the residence time calculator gives the retention time of a tank and the dilution calculator prepares samples for the BOD test.

Frequently asked questions

What is the F/M ratio?

The food to microorganism ratio compares the daily BOD load with the mass of microorganisms in the aeration tank. A conventional plant runs at 0.2 to 0.4 per day. A lower value gives good settling and nitrification but needs more tank volume, and a higher value can cause poor settling.

What is the sludge age?

It is the average time that a particle of sludge stays in the system, also called the solids retention time (SRT) or mean cell residence time. It is controlled by the amount of sludge wasted every day. A longer age lets slow-growing nitrifying bacteria stay in the plant.

What is a good SRT?

For BOD removal, 3 to 5 days can be enough. For nitrification, 8 to 15 days or more is typical in warm weather, and more in the cold. Extended aeration plants run at 20 to 30 days and produce less sludge.

What is MLVSS?

It is the mixed liquor volatile suspended solids, a measure of the organic part of the solids in the aeration tank, taken as an approximation of the microorganisms. MLSS also includes the inert fraction, and the ratio of the two is usually 70 to 80 percent.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.