Alkalinity tells how much acid water can absorb before its pH falls. The alkalinity titration calculator converts a titration to pH 4.5 into the total alkalinity in mg/L as CaCO₃, in meq/L, in carbonate hardness (°dKH) and in bicarbonate, from the sample volume, the acid normality and the acid volume.
How the calculation works
- Enter the volume of the water sample, the normality of the standard acid (0.02 N sulfuric acid is common) and the volume of acid needed to bring the sample to pH 4.5.
- The total alkalinity is A = V_acid × N × 50,000 / V_sample, in mg/L as calcium carbonate (CaCO₃).
- The calculator also gives it in milliequivalents per liter and as carbonate hardness, in German degrees (°dKH), the unit used in aquariums.
- The bicarbonate equivalent is the mass of HCO₃⁻ that has the same acid-neutralizing capacity.
Example
A 100 mL sample of tank water needs 3.6 mL of 0.02 N acid to reach pH 4.5. The alkalinity is 3.6 × 0.02 × 50,000 / 100 = 36.0 mg/L as CaCO₃, which is 0.72 meq/L, 2.02 °dKH and the equivalent of 43.9 mg/L of bicarbonate. That is a soft, weakly buffered water.
Why it matters
Alkalinity is measured in drinking-water plants, in pools, in aquariums, in boilers, in wastewater treatment and in agriculture. It decides how much acid or base is needed to change the pH, how corrosive or scaling the water is, and whether a biological process, such as nitrification, has enough buffering.
Good to know
The calculator assumes a titration with a strong acid to pH 4.5, and a total alkalinity expressed as CaCO₃, where 1 meq/L is 50 mg/L. The conversion to bicarbonate is exact only when the whole alkalinity is bicarbonate, which is the case for a pH under 8.3. Organic acids, phosphates, borates and silicates also contribute to the alkalinity of some waters. For a precise value, use a calibrated pH meter and a standardized acid, and note the temperature.
Related tools
The titration calculator covers the general acid–base titration, the water hardness calculator converts hardness units, the aquarium CO₂ calculator uses the alkalinity with the pH to find the dissolved CO₂, and the pKa ionization calculator covers the weak acids behind the buffering.