The forward converter calculator gives the duty cycle, the output inductor, the peak currents, the switch voltage and the rectifier reverse voltage of a single-switch forward converter with a reset winding.
How the calculation works
- Enter the input voltage, the output voltage and the output current.
- Enter the switching frequency, the turns ratio Np / Ns and the ripple ratio of the output inductor.
- The calculator finds the duty cycle, the inductance that gives the ripple, the currents in both windings and the voltages across the switch and the rectifier.
Example
A forward converter that turns 48 V into 12 V at 5 A, switching at 100 kHz with a turns ratio of 2, runs at a duty cycle of 50.0 %. A ripple of 30 % needs an output inductor of 40.0 µH. The primary peak current is 2.88 A, the secondary peak is 5.75 A, the switch sees 96 V and the forward rectifier 24 V.
Why it matters
The calculator helps power electronics students, designers of telecom and industrial supplies, and makers who need a 50 to 300 W isolated converter, since the forward topology gives a lower ripple and lower peak currents than a flyback at the same power.
Good to know
The 50 % duty cycle limit comes from the reset winding: if the duty cycle goes above it, the core does not demagnetize and saturates. A lower input voltage needs a duty cycle closer to the limit, so take the turns ratio at the minimum input voltage and check the switch rating at the maximum. Real converters add a voltage spike from the leakage inductance, a snubber loss and the forward voltage drop of the diodes. Use a freewheel diode or a synchronous rectifier on the secondary and check the temperature of the transformer, the output inductor and the switch on a prototype.