How much shielding will cut the dose rate?

Enter the dose rate, the shield thickness and the half-value layer of the material: get the dose behind the shield, the transmission and the thickness needed for a target.

Updated on
Your inputs

Value out of range

Value out of range

Value out of range

Value out of range

Results

Dose rate behind the shield

118.51 µSv/h

The dose rate is still above your target: add shielding

Thickness needed for your target

4.32 cm

Share of the radiation transmitted
11.85%
Number of half-value layers
3.08
Tenth-value layer (reduces the rate by 10)
2.16 cm
Linear attenuation coefficient
1.066 cm⁻¹

When gamma rays or X-rays pass through matter, their intensity drops exponentially. The half-value layer (HVL) is the thickness of a material that cuts the dose rate in half, and it is the handiest way to size a radiation shield. Enter the thickness of the shield, the HVL of the material at your radiation energy and the dose rate without shielding: the calculator gives the dose rate behind it, and the thickness needed to reach a target.

How the calculation works

  • Number of half-value layers = thickness ÷ HVL
  • Transmission = 0.5^(thickness ÷ HVL), equal to e^(−μ × thickness)
  • Dose rate behind the shield = initial dose rate × transmission
  • Tenth-value layer = HVL × log₂(10), about 3.32 HVL
  • Thickness for a target = HVL × log₂(initial rate ÷ target)

Example

A source gives 1,000 µSv/h, and a lead shield of 2 cm is placed in front of it. The half-value layer of lead for caesium-137 gamma rays is about 0.65 cm, so the shield is 3.08 layers thick. Only 11.86% of the radiation passes, leaving 118.6 µSv/h. To reach a target of 10 µSv/h, you need 4.32 cm of lead. The tenth-value layer is 2.16 cm.

Typical values

For the 662 keV gamma rays of caesium-137, the half-value layer is roughly 0.65 cm of lead, 1.6 cm of steel and 4.8 cm of concrete. Dense materials such as lead and steel shield best per centimetre, while concrete and water are used where thickness is cheap. Values change with energy, so always check the figure for your source.

Good to know

This is a simple model for a narrow beam. A real shield also deals with scattered radiation, gaps, leakage around the edges and the distance to the source, which falls with the square of the distance. Radiation protection is regulated: dose limits, monitoring and the design of shielding are decided by qualified radiation protection officers. Use this calculator for learning and rough estimates only.

For the effect of distance, use the inverse square law calculator, and for the decay of a source over time, the radioactive decay calculator. The Beer-Lambert calculator applies the same exponential law to light.

Frequently asked questions

What is a half-value layer?

The thickness of a material that reduces the intensity of a radiation beam to half. Each additional half-value layer halves it again, so 3 layers leave one eighth.

What is a tenth-value layer?

The thickness that cuts the intensity to one tenth. It equals about 3.32 half-value layers.

Why does the half-value layer depend on the energy?

High-energy photons penetrate more, so the layer is thicker. Look up the value for your source and material in a reference table or the isotope data sheet.

Does this work for all radiation?

It applies to a narrow beam of X-rays or gamma rays. In a broad beam, scattered radiation adds to the dose, and a buildup factor is needed. Alpha and beta particles are stopped in a very different way.