Skip to content
Omnikalc

Impedance matching calculator: match a source to a load without reflections

Enter the source and load impedances, the frequency and the velocity factor to get the quarter-wave transformer impedance and length, the L-network inductor and capacitor, the SWR and the mismatch loss.

Updated on
Your inputs
Ω

Value out of range

Ω

Value out of range

MHz

Value out of range

Value out of range

Results

Impedance of a quarter-wave transformer

100.00 Ω

Length of the quarter-wave section
11.43 ft
L-network: series inductor
970.6 nH
L-network: shunt capacitor
97.06 pF
Loaded Q of the L-network
1.732
SWR without matching
4.00
Mismatch loss without matching
1.938 dB

A source and a load that do not have the same impedance reflect part of the power. The impedance matching calculator gives two classical solutions: a quarter-wave transformer (the impedance and the length of the line section) and a low-pass L-network (the series inductor and the shunt capacitor). It also shows the SWR and the mismatch loss without matching.

How the calculation works

  • Enter the source impedance, the load impedance, the frequency and the velocity factor of the line.
  • A quarter-wave transformer is a section of line, a quarter of a wavelength long, with the impedance Z = √(Rs × RL).
  • An L-network has a series inductor on the low-impedance side and a shunt capacitor on the high-impedance side, with Q = √(R_high / R_low − 1), X_L = Q R_low and X_C = R_high / Q.
  • The calculator also gives the SWR and the mismatch loss that you would have without any matching.

Example

To match a 50 Ω source to a 200 Ω load at 14.2 MHz, a quarter-wave transformer needs a line of 100 Ω, 11.43 ft long for a velocity factor of 0.66. The L-network has Q = 1.732, a series inductor of 970.6 nH and a shunt capacitor of 97.06 pF. Without matching, the SWR is 4:1 and the mismatch loss is 1.938 dB.

Why it matters

Matching is needed in antennas, amplifiers, filters and transmission lines, wherever two parts of different impedance meet. The two methods here are the first tools of a radio amateur and of an RF designer, and they give the starting values for a more detailed design.

Good to know

The calculator is for purely resistive source and load, at a single frequency. The quarter-wave transformer is exact only at its design frequency, and the L-network values assume ideal components with no losses and no parasitic elements, which matters above about 100 MHz. If the load has a reactive part, it must be tuned out first. The length of the line section uses the velocity factor entered, and for a very high frequency, the effects of the layout must be taken into account.

The SWR calculator gives the standing wave ratio and the return loss of any mismatch, the coax electrical length calculator cuts a cable to the right length, the RC filter calculator covers the other use of reactive components, and the RLC impedance calculator covers the impedance of reactive networks.

Frequently asked questions

Why does impedance matching matter?

Maximum power is transferred from a source to a load when the load impedance equals the source impedance (for resistive loads), and on a transmission line a mismatch reflects part of the wave back to the source. The reflections cause standing waves, loss of power, ghost images on video lines and, in a transmitter, a risk of damage to the final amplifier.

How does a quarter-wave transformer work?

A line a quarter of a wavelength long inverts the impedance: a load RL is seen from the input as Z² / RL. To get a source resistance Rs, the line impedance must be Z = √(Rs RL). It works exactly at one frequency, and over a bandwidth of about 10 to 20 % with a low SWR. Longer sections (3/4 of a wavelength) also work but with a narrower bandwidth.

What is an L-network?

An L-network is the simplest matching circuit, made of one inductor and one capacitor in the shape of an L. It matches two different resistances at a single frequency, and its Q is fixed by the ratio of the resistances: Q = √(R_high/R_low − 1). There are four versions, depending on which element is in series and which in parallel, and the low-pass version here also attenuates the harmonics.

What is the mismatch loss?

It is the power lost by the reflection when the source and the load are not matched: ML = −10 log₁₀(1 − Γ²), with Γ = (RL − Rs)/(RL + Rs). A 2:1 SWR costs 0.51 dB, 3:1 costs 1.25 dB and 4:1 costs 1.94 dB. It is a loss at the junction only: the power that is reflected can often be re-reflected by the source and then reach the load, so the real loss may be lower.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.