Skip to content
Omnikalc

Kinematic viscosity calculator: from dynamic viscosity and density to centistokes

Enter the dynamic viscosity in centipoise and the density to get the kinematic viscosity in centistokes, stokes, m²/s and ft²/s, and the approximate Saybolt Universal Seconds.

Updated on
Your inputs
cP (mPa·s)

Value out of range

kg/m³

Value out of range

Results

Kinematic viscosity

172.41 cSt (mm²/s)

Kinematic viscosity in stokes
1.7241 St
Kinematic viscosity in SI units
0.0001724 m²/s
Kinematic viscosity in imperial units
0.001856 ft²/s
Approximate Saybolt Universal Seconds (SUS)
799 SUS
Dynamic viscosity in pascal-seconds
0.1500 Pa·s

Kinematic viscosity is the dynamic viscosity divided by the density, ν = μ / ρ. The kinematic viscosity calculator converts a viscosity in centipoise and a density into centistokes, stokes, m²/s and ft²/s, and gives the approximate Saybolt Universal Seconds.

How the calculation works

  • Enter the dynamic (absolute) viscosity of the fluid in centipoise (cP), which is the same as millipascal-seconds (mPa·s).
  • Enter the density of the fluid in kilograms per cubic meter at the same temperature as the viscosity.
  • The calculator divides the dynamic viscosity by the density: ν = μ / ρ.
  • It gives the kinematic viscosity in centistokes (cSt), in stokes, in m²/s and ft²/s, and the approximate Saybolt Universal Seconds.

Example

A lubricating oil has a dynamic viscosity of 150 cP and a density of 870 kg/m³ at the test temperature. The kinematic viscosity is 150 × 1000 / 870 = 172.41 cSt, which is 1.7241 St, 1.724 × 10⁻⁴ m²/s and 1.856 × 10⁻³ ft²/s. In Saybolt Universal Seconds it is about 799 SUS. The dynamic viscosity is 0.15 Pa·s.

Why it matters

The calculator helps engineers, mechanics, lubrication technicians and students to convert between the viscosity units found in data sheets, to check the grade of an oil and to prepare the inputs of a pipe flow or a Reynolds number calculation. It saves the unit conversions.

Good to know

The result is valid at the temperature at which the viscosity and the density were measured. It is for Newtonian fluids, which have a constant viscosity at a given temperature and pressure, and not for fluids such as paint, blood or polymer solutions, whose viscosity depends on the shear rate. The SUS value is an approximation for a test at 100 °F.

The water viscosity calculator gives the viscosity of water at a temperature, the air viscosity calculator does it for air, the Reynolds number calculator uses the kinematic viscosity to find the flow regime, and the pipe flow velocity calculator gives the flow speed.

Frequently asked questions

What is kinematic viscosity?

Kinematic viscosity is the ratio of the dynamic viscosity of a fluid to its density, ν = μ / ρ. The dynamic viscosity measures the internal resistance to shear, and dividing by the density gives how fast the momentum diffuses in the fluid. The SI unit is the square meter per second (m²/s). It is the property used for lubricating oils, fuels and hydraulic fluids, and in the Reynolds number of a flow.

What are the units of kinematic viscosity?

The SI unit is m²/s. The common practical unit is the centistoke (cSt), which equals 1 mm²/s, since 1 m²/s equals 1,000,000 cSt. The stoke (St) is 100 cSt, or 1 cm²/s. In the imperial system, ft²/s is used (1 m²/s is 10.7639 ft²/s). Dynamic viscosity is given in pascal-seconds (Pa·s) or in centipoise (cP), where 1 cP equals 1 mPa·s.

How do I convert centistokes to Saybolt seconds?

The Saybolt Universal Seconds (SUS) is the time for 60 ml of oil to flow out of a standard orifice at a given temperature, usually 100 °F. For a viscosity of 32 cSt or more, SUS is about 4.632 times the number of centistokes. The calculator uses the ASTM D2161 equation, which also works for lower viscosities. The result is for a viscosity measured at 100 °F (37.8 °C).

Why must the density be at the same temperature?

Both the viscosity and the density change with the temperature, and viscosity changes much faster: the viscosity of an oil can drop by a factor of ten between 40 °C and 100 °C, while the density changes by only a few percent. Use the density that is measured at the same temperature as the viscosity, otherwise the kinematic viscosity will have an error.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.