Log reduction: how many germs does a treatment remove?

Convert counts before and after a treatment into a log reduction and a percentage, and find how many survivors a given log reduction leaves.

Updated on
Your inputs
CFU

Value out of range

CFU

Value out of range

log

Value out of range

Results

Log reduction

5 log

4 logs or more: typical claim for disinfectants against viruses and bacteria
Percent reduction
99.999 %
Survivors at the target log reduction
1 CFU

What a log reduction is

Disinfection, sterilization and water treatment remove microbes by factors of ten. A log reduction counts those factors:

Log reduction = log10(N0 ÷ N)

where N0 is the number of microorganisms before treatment and N the number after, usually in colony-forming units (CFU). A 1-log reduction divides the count by 10, a 2-log reduction by 100, and so on.

Log reduction Percentage removed Survivors out of 1,000,000
1 90% 100,000
2 99% 10,000
3 99.9% 1,000
4 99.99% 100
5 99.999% 10
6 99.9999% 1

Example

A surface carries 1,000,000 CFU before cleaning and 10 CFU after. The log reduction is log10(1,000,000 ÷ 10) = 5, or 99.999%.

Why “99.9% of germs” is less impressive than it sounds

A 3-log reduction still leaves 1,000 survivors out of a million. For pathogens that cause infection at low doses, such as norovirus, the remaining 0.1% can matter. That is why standards set targets of 4, 5 or 6 logs depending on the use.

Where the targets come from

  • Disinfectants: EPA test methods and European standards such as EN 1276 (a 5-log reduction for bacteria) and EN 14476 (a 4-log reduction for viruses).
  • Sterilization: a sterility assurance level of 10⁻⁶, a one-in-a-million chance that a single viable microbe remains, is the usual target for medical devices.
  • Drinking water: US rules require at least 3-log removal or inactivation of Giardia and 4-log of viruses for treated surface water.
  • Food: juice processors must achieve a 5-log reduction of the target pathogen.

Reading a result

Log reductions are only meaningful if the starting count is high enough. If you start with 1,000 CFU, you cannot demonstrate more than a 3-log reduction, because you cannot count fewer than one survivor. Tests therefore use high inocula, often 10⁶ to 10⁸ CFU.

Contact time matters

Every log reduction claim is tied to a concentration, a temperature and a contact time. A disinfectant that achieves 5 logs in 5 minutes may achieve much less in 30 seconds, so follow the label.

Frequently asked questions

What is a 3-log reduction?

A reduction by a factor of 1,000, which removes 99.9% of microorganisms.

How do you calculate log reduction?

Log reduction = log10(count before ÷ count after). From 1,000,000 to 10 CFU, it is 5 logs.

How do you convert log reduction to percent?

Percent reduction = (1 − 10^−log) × 100. 4 logs is 99.99% and 6 logs is 99.9999%.

What log reduction does sterilization require?

Medical device sterilization usually aims for a sterility assurance level of 10⁻⁶, typically shown with a 6-log or greater reduction.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.