A proton-exchange membrane (PEM) fuel cell turns hydrogen and oxygen into electricity, water and heat. One cell gives less than one volt, so cells are stacked in series. This calculator takes the number of cells, their area, the current density and the cell voltage read on a polarization curve, and returns the power, the hydrogen consumption, the efficiency, the air flow and the heat to evacuate.
How the calculation works
- Stack current = current density × cell area
- Stack voltage = number of cells × cell voltage
- Power = stack voltage × stack current
- Hydrogen use = N × I ÷ (2F), with F = 96,485 C/mol, then × 2.016 g/mol
- Oxygen use = N × I ÷ (4F); air = stoichiometry × oxygen ÷ 0.21
- Efficiency (LHV) = cell voltage ÷ 1.253 V
- Waste heat = N × I × (1.253 − cell voltage)
Example
A stack of 100 cells of 200 cm² at 0.6 A/cm² carries 120 A. With 0.65 V per cell, the stack voltage is 65.0 V and the power is 7.80 kW. It consumes 0.451 kg of hydrogen an hour, and each kilogram gives 17.3 kWh of electricity, an efficiency of 51.9 % on the lower heating value (33.3 kWh/kg). It produces 4.03 kg of water per hour and 7.24 kW of heat, which a cooling circuit must remove. The air flow at a stoichiometry of 2 is 398 L/min.
Why it matters
The voltage per cell sets the trade-off between efficiency and power. Lower voltage means higher current and more power from the same stack, but more heat and more hydrogen per kWh. Designers pick the operating point from the polarization curve: at low current the cell is efficient and the stack is large, and at high current it is compact and wasteful. The heat output is nearly as large as the electric output, so thermal management is as important as the stack.
Good to know
The 1.253 V reference corresponds to the lower heating value of hydrogen; on the higher heating value the reference is 1.48 V. The tool does not include the power used by compressors, humidifiers and pumps, which can take 10 to 25 % of the output. Voltage depends on temperature, pressure and humidity, and it declines with age. The air flow uses 22.414 L/mol at normal conditions, so the real volume at the operating pressure will be different.
In practice
Use the calculator for a first design: choose the target power and cell voltage, then scale the cells and the area. For hydrogen supply, multiply the consumption by the running hours. The tool is for sizing and education, not a safety design.