Skip to content
Omnikalc

Radiative heat exchange calculator: how much heat do two plates and a shield exchange?

Enter the plate temperatures and emissivities and the number of radiation shields to get the net radiative heat flux with and without shields.

Updated on
Your inputs
°F

Value out of range

°F

Value out of range

Value out of range

Value out of range

Value out of range

Value out of range

Results

Net radiative heat flux with the shields

10.07 BTU/h·ft²

Net radiative heat flux without shields
533.6 BTU/h·ft²
Reduction of the heat transfer
98.1 %
Effective emissivity with the shields
0.0126

Radiation between two surfaces depends on the fourth power of their absolute temperatures and on their emissivities. This radiative heat exchange calculator finds the net radiative heat flux between two large parallel plates, with radiation shields placed between them if you want. It gives the flux with and without the shields, the reduction and the effective emissivity.

How the calculation works

  • Enter the temperatures and the emissivities of two large parallel plates, the number of radiation shields between them and the emissivity of the shields.
  • Without shields, the net flux is q = σ (T₁⁴ − T₂⁴) / (1/ε₁ + 1/ε₂ − 1), with temperatures in kelvin and σ = 5.67 × 10⁻⁸ W/m²·K⁴.
  • Each shield adds (2/ε₃ − 1) to the denominator, so the flux with N shields is q = σ (T₁⁴ − T₂⁴) / (1/ε₁ + 1/ε₂ − 1 + N (2/ε₃ − 1)).
  • The calculator shows the flux with and without the shields, the reduction and the effective emissivity of the whole stack.

Example

Two plates at 400 °F and 70 °F with an emissivity of 0.8 exchange 533.6 BTU/h·ft² without shields. With 2 shields of emissivity 0.05, the denominator rises from 1.5 to 79.5, and the flux falls to 10.1 BTU/h·ft², a reduction of 98.1 %.

Why it matters

Radiation shields are used in furnaces, cryogenic tanks, space vehicles, thermos bottles, ovens and also in a car exhaust shield. The calculator shows how much a few thin sheets reduce the radiative loss, and why a low emissivity matters more than the number of sheets. It is also a good exercise for heat transfer classes.

Good to know

The calculator treats two large, parallel, gray, diffuse surfaces with uniform temperature, in a medium that does not absorb radiation, and shields that are thin and have the same emissivity on both sides. Edge effects, other surfaces in view, a shield that touches a plate and the change of emissivity with temperature and wavelength are not included. The shield temperatures are not required for the flux, since the shield resistances add up in series.

The blackbody radiation calculator covers the Stefan–Boltzmann law for one surface, the heat conduction calculator covers the other mode of transfer through solids, Newton’s law of cooling covers convection, and the Carnot efficiency calculator covers the limits of heat engines.

Frequently asked questions

How do radiation shields work?

A shield is a thin sheet of low-emissivity material placed between two hot and cold surfaces. It absorbs little, reflects most of the radiation, and takes a temperature between the two. Each shield adds a resistance to the radiative exchange. With N identical shields of the same emissivity as the plates, the flux falls to 1/(N + 1) of the value without shields.

Why does a low emissivity matter so much?

The resistance of each shield is (2/ε₃ − 1), which grows quickly as the emissivity falls: 1 for a black surface, 3 for ε = 0.5 and 39 for ε = 0.05. A polished aluminum or gold sheet is therefore a good shield. This is also the reason for the multilayer insulation of spacecraft and the silvered walls of a thermos bottle.

What is the effective emissivity?

It is the single emissivity that gives the same exchange between two plates as the whole set of surfaces, ε = 1 / (1/ε₁ + 1/ε₂ − 1 + N(2/ε₃ − 1)). It makes the equation of the flux look like that of two black surfaces, multiplied by this factor.

Do shields work in all cases?

They work against radiation, not against conduction or convection. In a vacuum, as in a thermos bottle, a cryostat or a satellite, they are very effective. In air, convection and conduction across the gap add heat transfer that shields do not reduce, so the total reduction is lower than the value shown.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.