Skip to content
Omnikalc

Reactor volume calculator: how big must a CSTR or a PFR be for your conversion?

Choose a CSTR or a PFR and enter the flow rate, the first-order rate constant and the conversion to get the reactor volume, the residence time and the Damköhler number.

Updated on
Your inputs
gpm

Value out of range

per min

Value out of range

%

Value out of range

Results

Reactor volume needed

4,500 gal

Residence time
45.0 min
Damköhler number Da = k × τ
9.00
Volume of a CSTR
4,500 gal
Volume of a PFR
1,151 gal
CSTR volume ÷ PFR volume
3.91 ×

The size of a chemical reactor depends on the speed of the reaction, the flow and the conversion needed, and also on the kind of reactor. The reactor volume calculator takes the reactor type, the flow rate, the first-order rate constant and the conversion, and gives the reactor volume, the residence time, the Damköhler number, the volumes for both a CSTR and a PFR and their ratio.

How the calculation works

  • Choose the reactor type, a continuous stirred tank (CSTR) or a plug flow reactor (PFR), and enter the flow rate, the first-order rate constant and the conversion that you want.
  • For a first-order reaction, a CSTR needs a residence time τ = X / (k (1 − X)), and a PFR needs τ = −ln(1 − X) / k, where X is the fraction converted.
  • The reactor volume is the flow rate times the residence time, V = Q × τ.
  • The calculator also gives the Damköhler number Da = k τ and the volumes for both types, so you can compare them.

Example

A liquid-phase first-order reaction with k = 0.2 per min is run at 100 gpm to a conversion of 90 %. A CSTR needs τ = 0.9 / (0.2 × 0.1) = 45 min, which is a volume of 4,500 gal. A PFR needs only τ = −ln(0.1) / 0.2 = 11.5 min, which is 1,151 gal. The CSTR is 3.9 times larger. The Damköhler number of the CSTR is 9.0.

Why it matters

Reactor sizing is one of the first steps in the design of a chemical process. The comparison of the two ideal reactors shows why a plug flow reactor is smaller for the same job, and how much extra volume a stirred tank needs at high conversion. The calculator is useful for students of chemical engineering and for a first estimate of a pilot plant.

Good to know

The calculator is for an irreversible, first-order reaction in a liquid of constant density at constant temperature, in ideal reactors with perfect mixing or perfect plug flow. Real reactors have dead zones, short-circuiting and a distribution of residence times, and many reactions are of a different order, reversible or exothermic. The volume is the one for the reacting fluid and does not include the free space or the safety margin.

The Arrhenius equation calculator gives the effect of temperature on k, the residence time calculator covers the time in a vessel, the integrated rate law calculator covers the concentration over time, and the equilibrium constant calculator covers the limit of the reaction.

Frequently asked questions

What is the difference between a CSTR and a PFR?

In a continuous stirred-tank reactor, the contents are perfectly mixed, so the concentration everywhere equals the concentration at the outlet, which is low, and the reaction goes at its slowest rate. In a plug flow reactor, the fluid moves through a tube without mixing along the flow, and the concentration falls gradually from the inlet value, so the average rate is higher. For the same duty, a PFR is smaller.

Why is a CSTR bigger for a high conversion?

Because the reaction takes place at the low outlet concentration. For a first-order reaction, the CSTR volume grows as X / (1 − X), which goes up quickly as X nears 1, while the PFR grows as the logarithm of 1 / (1 − X). At 50 % conversion, the two are close (ratio 1.44), and at 99 % the CSTR is 21 times larger.

When is a CSTR used anyway?

A CSTR gives a uniform temperature, easy control and good mixing, which are useful for highly exothermic reactions, for slurries or for fermentations. Several CSTRs in series come close to a PFR, with N tanks of equal size needing less volume as N increases. Plug flow is better for fast gas-phase reactions and for large volumes.

What is the Damköhler number?

It is the ratio of the reaction rate to the flow rate, Da = k τ for a first-order reaction. A large value means that the reaction goes far in one pass through the reactor. For a CSTR, the conversion is X = Da / (1 + Da), and for a PFR it is X = 1 − e^(−Da). It is a handy way to compare reactors and operating conditions.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.