The size of a chemical reactor depends on the speed of the reaction, the flow and the conversion needed, and also on the kind of reactor. The reactor volume calculator takes the reactor type, the flow rate, the first-order rate constant and the conversion, and gives the reactor volume, the residence time, the Damköhler number, the volumes for both a CSTR and a PFR and their ratio.
How the calculation works
- Choose the reactor type, a continuous stirred tank (CSTR) or a plug flow reactor (PFR), and enter the flow rate, the first-order rate constant and the conversion that you want.
- For a first-order reaction, a CSTR needs a residence time τ = X / (k (1 − X)), and a PFR needs τ = −ln(1 − X) / k, where X is the fraction converted.
- The reactor volume is the flow rate times the residence time, V = Q × τ.
- The calculator also gives the Damköhler number Da = k τ and the volumes for both types, so you can compare them.
Example
A liquid-phase first-order reaction with k = 0.2 per min is run at 100 gpm to a conversion of 90 %. A CSTR needs τ = 0.9 / (0.2 × 0.1) = 45 min, which is a volume of 4,500 gal. A PFR needs only τ = −ln(0.1) / 0.2 = 11.5 min, which is 1,151 gal. The CSTR is 3.9 times larger. The Damköhler number of the CSTR is 9.0.
Why it matters
Reactor sizing is one of the first steps in the design of a chemical process. The comparison of the two ideal reactors shows why a plug flow reactor is smaller for the same job, and how much extra volume a stirred tank needs at high conversion. The calculator is useful for students of chemical engineering and for a first estimate of a pilot plant.
Good to know
The calculator is for an irreversible, first-order reaction in a liquid of constant density at constant temperature, in ideal reactors with perfect mixing or perfect plug flow. Real reactors have dead zones, short-circuiting and a distribution of residence times, and many reactions are of a different order, reversible or exothermic. The volume is the one for the reacting fluid and does not include the free space or the safety margin.
Related tools
The Arrhenius equation calculator gives the effect of temperature on k, the residence time calculator covers the time in a vessel, the integrated rate law calculator covers the concentration over time, and the equilibrium constant calculator covers the limit of the reaction.