Skip to content
Omnikalc

SCFM calculator: standard flow from ACFM, pressure and temperature

Enter the actual flow in ACFM, the gauge pressure and the gas temperature to get the standard flow in SCFM, the conversion ratio, the absolute pressure and the flow in cubic meters per minute.

Updated on
Your inputs
ACFM

Value out of range

psig

Value out of range

°F

Value out of range

Results

Standard flow

735.8 SCFM

Ratio of standard to actual flow
7.358
Absolute pressure
114.7 psia
Standard flow in cubic meters per minute
20.84 m³/min

A cubic foot of compressed air does not hold the same amount of air as a cubic foot at atmospheric pressure. SCFM puts flows on a common basis. This SCFM calculator takes the actual flow in ACFM, the gauge pressure and the gas temperature to give the standard flow in SCFM, the conversion ratio, the absolute pressure and the flow in cubic meters per minute.

How the calculation works

  • Absolute pressure = gauge pressure + 14.696 psi of atmosphere.
  • Pressure factor = absolute pressure ÷ 14.696. Compressed gas takes less volume, so it holds more standard cubic feet.
  • Temperature factor = 527.67 ÷ (°F + 459.67), the ratio of the standard temperature of 68 °F (527.67 °R) to the actual one.
  • SCFM = ACFM × pressure factor × temperature factor.

Example

A compressor delivers 100 ACFM at 100 psig and 100 °F. The absolute pressure is 114.696 psia, the pressure factor is 7.804 and the temperature factor is 527.67 ÷ 559.67 = 0.943. The standard flow is 100 × 7.804 × 0.943 = 735.8 SCFM, which is 20.8 m³/min.

Why it matters

Compressors, air tools, blowers, gas meters and flow controllers are rated in SCFM or in the equivalent normal cubic meters, and the number on the data sheet is meaningless without conditions. Converting lets you check that a compressor can supply your tools, size a regulator, compare quotes and compare a flow meter reading with a requirement.

Good to know

Standard conditions are not universal. Some suppliers use 60 °F and 14.73 psia, others 70 °F, and the difference can reach 2 to 3 %, so confirm what the data sheet uses. Humidity changes the gas mass slightly, and for air at high pressure the ideal gas law becomes less exact. A compressor’s rated flow is often free air delivery, which is the output expressed at intake conditions. Pressure drops in hoses and fittings reduce the pressure at the tool, which changes the flow it receives.

The ideal gas calculator links pressure, volume and temperature, the pressure tank calculator sizes an air receiver and the pneumatic cylinder calculator finds force and air use.

Frequently asked questions

What is SCFM?

Standard cubic feet per minute is a gas flow expressed at standard conditions, so that flows at different pressures and temperatures can be compared. It is a measure of the mass of gas, not of volume.

What is the difference between SCFM and ACFM?

ACFM is the volume of gas actually flowing at the existing pressure and temperature. SCFM is the volume that the same gas would take at standard conditions.

What are standard conditions?

This calculator uses 68 °F (20 °C) and 14.696 psia (1 atm). Other standards exist, including 60 °F and 14.73 psia, and the normal conditions used in Europe, 0 °C and 1.01325 bar.

Why does the pressure matter so much?

Gas at 100 psig is compressed to about one eighth of the volume it has at atmospheric pressure. A flow of 100 ACFM at that pressure carries as much gas as about 780 ACFM at atmospheric pressure.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.