Skip to content
Omnikalc

Second-order step response calculator: overshoot, settling time and rise time from ζ and ωn

Enter the damping ratio and the natural frequency of a second-order system to get the percent overshoot, peak time, settling time, rise time and damped frequency of its step response.

Updated on
Your inputs

Value out of range

rad/s

Value out of range

Results

Percent overshoot

16.30 %

Peak time
0.3628 s
Settling time (2 % band)
0.8000 s
Rise time (10 % to 90 %)
0.1900 s
Damped natural frequency
8.660 rad/s
Natural frequency in hertz
1.592 Hz
Damping ratio
0.50
Underdamped: the response overshoots and oscillates before it settles

How fast and how smooth is the response of a system to a sudden change? For a second-order system, two numbers tell: the damping ratio and the natural frequency. The second-order step response calculator gives the percent overshoot, the peak time, the settling time, the rise time and the damped frequency.

How the calculation works

  • Enter the damping ratio ζ and the natural frequency ωn (in rad/s) of the system. For a mass-spring-damper, ωn = √(k/m) and ζ = c / (2√(km)).
  • The calculator treats the standard second-order system G(s) = ωn² / (s² + 2ζωn s + ωn²), with a unit step as the input.
  • For ζ < 1 it gives the percent overshoot 100 e^(−πζ/√(1−ζ²)), the peak time π / (ωn √(1−ζ²)) and the damped frequency.
  • It also gives the 2 % settling time ≈ 4 / (ζ ωn) and the 10–90 % rise time, with the approximation (1 + 1.1ζ + 1.4ζ²) / ωn.

Example

A system has ζ = 0.5 and ωn = 10 rad/s. The overshoot is 100 e^(−π×0.5/√0.75) = 16.30 %, the peak occurs at 0.3628 s, the 2 % settling time is 4 / (0.5 × 10) = 0.8000 s, and the rise time is about 0.1900 s. The damped frequency is 8.660 rad/s and the natural frequency is 1.592 Hz.

Why it matters

The calculator helps students and engineers in control, electronics, mechanics and robotics to check a design against a specification, to see the trade-off between speed and overshoot and to tune a controller or a filter without a simulation.

Good to know

The formulas are for the standard second-order system without zeros, with a unit step input. Real systems have extra poles, zeros, delays and nonlinearities that change the response. The settling and rise times are approximations. A system with a high overshoot may saturate in practice. Use the calculator as a first estimate, and confirm with a simulation or a measurement.

The damping ratio calculator gives ζ for a mechanical system, the RLC impedance calculator covers the circuit, the LC resonance calculator finds the natural frequency of a tank, and the RC filter calculator covers the first-order case.

Frequently asked questions

What is a second-order system?

It is a system whose behavior is described by a differential equation of order two, such as a mass on a spring with a damper, an RLC circuit, a servo motor with its load or a pendulum with friction. Its response to a step input is set by two numbers: the natural frequency ωn, which tells how fast it reacts, and the damping ratio ζ, which tells how much it oscillates.

What do the damping regimes mean?

For ζ < 1 the system is underdamped: it overshoots and rings, and the lower the ζ the more it overshoots. For ζ = 1 it is critically damped: it reaches the final value as fast as possible without overshoot. For ζ > 1 it is overdamped: no overshoot, but slow. Many designs aim for ζ between 0.5 and 0.8, a compromise of speed and overshoot that gives about 16 % to 1.5 % of overshoot.

How accurate are the settling and rise times?

The overshoot and the peak time are exact formulas for ζ < 1. The settling time 4/(ζωn) is an approximation of the time to stay within 2 % of the final value, good for ζ under about 0.9. The rise time (1 + 1.1ζ + 1.4ζ²)/ωn is a fit that works for ζ between 0.3 and 0.8. For an overdamped system, these approximations are not valid, and the response is dominated by the slow pole.

How can I use it for a control design?

Choose the specifications first, for example an overshoot under 10 % and a settling time under 1 second. The overshoot gives a minimum ζ, about 0.59 for 10 %. The settling time then gives a minimum ζωn, here 4. Pick the poles of the closed loop to meet both. The calculator gives a quick check, and a simulation or a Bode plot of the real system gives the details.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.