Stokes shift calculator

Enter the wavelength of maximum absorption and of maximum emission to get the Stokes shift in nanometers, in wavenumbers and in electronvolts, and the share of the photon energy lost before emission.

Updated on
Your inputs
nm

Value out of range

nm

Value out of range

Results

Stokes shift

24.0 nm

Small shift: self-absorption is likely
Stokes shift in wavenumbers
934 cm⁻¹
Stokes shift in energy
0.1158 eV
Share of the photon energy lost
4.62 %
Share of the energy kept (Stokes efficiency)
95.38 %
Photon energy at absorption
2.5047 eV

The Stokes shift calculator gives the Stokes shift of a fluorescent molecule in nanometers, wavenumbers and electronvolts, and the share of the photon energy lost between absorption and emission.

How the calculation works

  • Enter the absorption maximum in nanometers.
  • Enter the emission maximum in nanometers.
  • The calculator gives the shift in three units, the energy lost, the energy kept and the absorbed photon energy.

Example

Fluorescein absorbs at about 495 nm and emits at about 519 nm. The shift is 24.0 nm. In wavenumbers, 10⁷ / 495 − 10⁷ / 519 = 934 cm⁻¹, and in energy 0.1158 eV. The absorbed photon has 2.5047 eV, so 4.62 % of it is lost and 95.38 % is kept.

Why it matters

The calculator helps chemistry and biology students, microscopists choosing filters for fluorescent labels, and researchers who compare dyes and quantum dots.

Good to know

The values depend on the solvent and on the environment of the molecule, since polar solvents often increase the shift. The maxima must be read from spectra measured in the same medium. A negative shift indicates anti-Stokes emission, which needs thermal or multiphoton energy and is rare. The energy fraction kept is the upper bound of the energy efficiency of fluorescence, before the quantum yield is taken into account. Together with the quantum yield, it gives the overall efficiency of converting absorbed light energy into emitted light. For narrow shifts, as for fluorescein, the overlap of the absorption and emission bands causes self-absorption at high concentration. Always read the maxima on spectra recorded with the same bandwidth and in the same solvent, and prefer the peak of the energy scale when you compare dyes, because the peak positions on a wavelength scale and on a wavenumber scale differ slightly.

The quantum yield calculator measures fluorescence efficiency, the photon energy calculator converts wavelength to energy, the wavelength calculator relates wavelength and frequency and the Beer-Lambert calculator links absorbance and concentration.

Frequently asked questions

What is the Stokes shift?

It is the difference between the wavelength of maximum absorption and that of maximum emission of a fluorescent molecule. The molecule loses some energy as heat before emitting, so the emitted light is redder than the absorbed light.

Why express it in wavenumbers?

Wavenumber and energy are proportional, while wavelength is not, so a 24 nm shift is not the same energy at 400 nm and at 700 nm. In cm⁻¹, shifts of different dyes can be compared fairly. The conversion is 10⁷ divided by the wavelength in nanometers.

Is a large shift good?

For imaging, yes. A large shift separates the excitation light from the emission, so filters block the first and keep the second with less background, and the dye reabsorbs less of its own light. The price is more energy lost as heat.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.