The fluorescence quantum yield calculator gives the quantum yield of a sample by the relative method, from a reference dye, the integrated emission and absorbance of both, and the refractive indices of the solvents.
How the calculation works
- Enter the quantum yield and the integrated emission of the reference and of the sample.
- Enter the absorbances at the excitation wavelength and the refractive indices.
- The calculator gives the quantum yield, its percentage, the relative emission, the highest absorbance and the index correction.
Example
A reference with a yield of 0.54 gives 1,000 units, and the sample gives 850 at the same absorbance of 0.05. The solvents have indices of 1.36 and 1.333, so the correction is 1.0409. The quantum yield is 0.54 × 0.85 × 1 × 1.0409 = 0.4778, or 47.8 %: the sample emits 0.885 times the reference per absorbed photon.
Why it matters
The calculator helps chemistry and biology students, researchers who characterize fluorescent dyes, probes or quantum dots, and laboratories that check the brightness of new materials.
Good to know
Use integrated emission spectra, the area under the whole curve, corrected for the instrument response, and not the intensity at one wavelength. Subtract the blank solvent signal. Measuring several dilutions and using the slope of the integrated emission against absorbance, rather than a single point, gives a more reliable value and checks for linearity. The refractive index correction matters when the solvents differ, for example water for the reference and ethanol or toluene for the sample. Temperature, oxygen and pH can all change the yield. Report the reference and the excitation wavelength together with the result, since the yield may depend on both.