Skip to content
Omnikalc

Toroid inductance calculator

Enter the turns, the core permeability, the core dimensions and the current to get the inductance, the flux density and the margin to saturation.

Updated on
Your inputs

Value out of range

Value out of range

mm

Value out of range

mm

Value out of range

mm

Value out of range

A

Value out of range

T

Value out of range

Results

Inductance

13.86 mH

Mean magnetic path length
94.2 mm
Magnetizing field
106.1 A/m
Flux density in the core
0.133 T
Margin to saturation
62 %
Stored energy
0.069 mJ

The toroid inductance calculator gives the inductance of a coil wound on a ring core, the magnetic path length, the flux density, the margin to saturation and the stored energy.

How the calculation works

  • Enter the number of turns, the relative permeability of the core and its inner radius, outer radius and height.
  • Enter the current and the saturation flux density of the core material.
  • The calculator gives the inductance, the magnetizing field and the flux density, then compares the flux density with saturation.

Example

A toroid of 100 turns on a core of permeability 1000, with radii of 10 mm and 20 mm and a height of 10 mm, has an inductance of 13.86 mH. With 0.1 A the flux density is 0.133 T, which leaves a margin of 62 % before the core saturates at 0.35 T. The coil stores 0.069 mJ.

Why it matters

The calculator helps electronics designers who wind chokes, common-mode filters and transformers on toroidal cores, hobbyists who wind their own coils for radios and power supplies, and students who study the magnetic circuit.

Good to know

A ring core is popular because the winding fills a closed magnetic path, so the stray field and the coupling to nearby parts are low. The inductance rises with the square of the turns, so a few more turns change it a lot. Keep the flux density below the saturation level with a margin of at least 20 %, also at the peak of the current and at the highest temperature, because the saturation level of a ferrite falls when it is hot. A powder core tolerates a higher current than a ferrite of the same size. Check the winding space, which limits the number of turns for a given wire, and the copper loss of the winding.

The solenoid inductance calculator covers the air-core coil, the inductors in series and parallel calculator combines coils, the Faraday induction calculator gives the voltage induced by a changing flux and the transformer calculator gives the ratios of two windings.

Frequently asked questions

What is the inductance of a toroid?

For a toroid with a rectangular cross-section, an inner radius a, an outer radius b and a height h, the inductance is L = μ0 × μr × N² × h × ln(b / a) / (2 × π). It grows with the square of the number of turns and in proportion to the permeability of the core. A toroid keeps nearly all of its flux inside the core, so it radiates very little.

What is the flux density in the core?

The magnetizing field on the mean path is H = N × I / lm, with lm = π × (a + b). The flux density is B = μ0 × μr × H as long as the core is not saturated. The calculator compares B with the saturation level, which you take from the data sheet: about 0.3 to 0.5 T for ferrite, 1.2 to 1.5 T for powder and 1.5 to 2 T for silicon steel.

What happens at saturation?

When the flux density reaches the saturation level, the permeability of the core drops, the inductance falls and the current rises sharply for a small increase of the voltage. In a power supply this can destroy the switch. A gapped core or a powder core has a lower permeability and a softer saturation, which is why they are used for chokes.

How accurate is the result?

The formula uses a constant permeability and an ideal winding. Real cores have a permeability that depends on the field, the frequency and the temperature, with a tolerance of 20 % or more, and the winding has its own leakage. Use the result to pick a core and a number of turns, then measure the inductance of the finished part.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.