Vacuum pump-down time calculator: time to reach a pressure with a given pump

Enter the chamber volume, the pumping speed, the starting and target pressures and the ultimate pressure to get the pump-down time, the time constant and the pressure after a given time.

Updated on
Your inputs
ft³

Value out of range

cfm

Value out of range

Torr

Value out of range

Torr

Value out of range

Torr

Value out of range

s

Value out of range

Results

Pump-down time to the target

3:21

Time constant V / S
30.0 s
Pressure after the elapsed time
102.90 Torr
Target pressure divided by the ultimate pressure
20.0
Reachable with a margin over the ultimate pressure

The pump-down time is how long a vacuum pump takes to lower the pressure of a chamber to a target. The vacuum pump-down time calculator gives the time from the volume, the pumping speed, the pressures and the ultimate pressure, with the time constant and the pressure after a given time.

How the calculation works

  • Enter the volume of the chamber and the pumping speed of the pump at the chamber (after the loss of the pipes and the valves).
  • Enter the starting pressure (760 Torr for atmospheric air) and the target pressure.
  • Enter the ultimate pressure that the system can reach, set by the leaks, the outgassing of the walls and the pump itself.
  • The pressure falls exponentially toward the ultimate pressure: p(t) = pu + (p1 − pu) e^(−S t / V). The calculator gives the time to the target, the time constant and the pressure after a given time.

Example

A chamber of 3 ft³ is pumped with a speed of 6 cfm from 760 Torr to 1 Torr, with an ultimate pressure of 0.05 Torr. The time constant is V / S = 3 / 6 = 0.5 min, or 30 s. The time to the target is 30 × ln((760 − 0.05) / (1 − 0.05)) = 30 × ln 800 = 200.5 s, or about 3 min 21 s. After 60 s, the pressure is 0.05 + 759.95 × e^(−2) = 102.9 Torr. The target is 20 times the ultimate pressure, a comfortable margin.

Why it matters

The calculator helps technicians, makers, laboratory staff and students to choose a pump for a vacuum chamber, a degassing tank, a vacuum former or a food-packaging machine, and to estimate the cycle time. It also shows how the leaks limit the final pressure.

Good to know

Use the real speed at the chamber, not the speed of the pump on the label. Look for the leaks first if the pressure stops falling early: a leak sets the ultimate pressure. Allow extra time for the outgassing of water in a chamber that was open to humid air. Keep the units consistent for the speed and the volume.

The ideal gas calculator relates pressure, volume and temperature, the combined gas law calculator compares two states, the gas molecule speed calculator gives the thermal velocity, and the hydrostatic pressure calculator gives the pressure of a column of fluid.

Frequently asked questions

How is the pump-down time computed?

In the rough vacuum range, with a constant pumping speed S, the pressure falls exponentially: p(t) = pu + (p1 − pu) e^(−S t / V). Solving for the time gives t = (V / S) ln((p1 − pu) / (p2 − pu)). The ratio V / S is the time constant. Each time constant lowers the excess pressure over the ultimate pressure by a factor of e, about 2.7, and each decade of pressure takes 2.3 time constants.

What is the ultimate pressure?

It is the lowest pressure that the system can reach. It is set by the pump itself, by the leaks of the chamber and the joints, and by the outgassing of the walls, the seals and the contents (water vapor is the main source). With a throughput Q of leaks and outgassing, the ultimate pressure is pu = Q / S. A target close to pu takes a very long time, and a target below it is not reachable with this pump.

Why is the effective pumping speed lower than the pump speed?

The tubing, the valves and the traps between the pump and the chamber limit the flow, and the effective speed is S = 1 / (1 / Sp + 1 / C), where Sp is the speed of the pump and C the conductance of the line. A narrow or long line can halve the speed. Use short, wide lines for the best performance. Enter the speed at the chamber in this calculator.

Does this apply to high vacuum?

No. The formula holds for the viscous (rough vacuum) range, roughly above 0.1 Torr, with a pump of constant speed. In high vacuum, the speed of the pumps changes with the pressure, the gas flow is molecular and the outgassing dominates, so the pump-down is no longer exponential. For those ranges, use the data of the pump and a more detailed model.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.