Venturi meter: flow rate from the pressure difference

Find the flow rate through a Venturi tube from the inlet and throat diameters and the measured pressure drop, using Bernoulli's equation with a discharge coefficient.

Updated on
Your inputs

Value out of range

Value out of range

Value out of range

kg/m³

Value out of range

Value out of range

Results

Flow rate

270

Ideal-flow estimate corrected by the discharge coefficient
Velocity at the throat
28.1
Velocity in the pipe
7.03
Beta ratio d₂ / d₁
0.5

How a Venturi meter measures flow

A Venturi tube is a section of pipe that narrows through a converging cone to a short throat, then widens again through a longer diverging cone. Named after the Italian physicist Giovanni Battista Venturi and turned into a practical water meter by Clemens Herschel in 1887, it is still used for water, wastewater, gas and process flows.

As the fluid enters the throat, it speeds up to keep the same flow rate through a smaller area. By Bernoulli’s principle, its pressure falls. Two pressure taps, one upstream and one at the throat, measure that difference Δp, which grows with the square of the flow.

The equation

Combining continuity and Bernoulli’s equation for an incompressible fluid gives the throat velocity and the flow rate:

v₂ = √(2Δp ÷ (ρ(1 − β⁴)))

Q = Cd × A₂ × v₂

where:

  • β is the diameter ratio d₂ ÷ d₁;
  • A₂ is the throat area, π d₂² ÷ 4;
  • ρ is the fluid density (1000 kg/m³ for water);
  • Cd is the discharge coefficient.

The inlet velocity is v₁ = v₂ × β².

Example

A 4-inch pipe with a 2-inch throat (β = 0.5) carrying water with a 5 psi pressure difference gives a throat velocity of about 28 ft/s (8.6 m/s). With a discharge coefficient of 0.98, the flow is about 1,020 L/min, or 270 US gallons per minute. The inlet velocity is a quarter of the throat velocity, about 7 ft/s (2.1 m/s).

Choosing the discharge coefficient

Device Typical Cd
classical Venturi, machined convergent about 0.995
classical Venturi, cast or welded about 0.98 to 0.985
flow nozzle about 0.95 to 0.99
sharp-edged orifice plate about 0.6

The values for standard devices are given in ISO 5167, which also sets the geometry, the diameter ratio (about 0.3 to 0.75 for Venturis) and the straight pipe lengths needed upstream.

Limits

  • The formula assumes an incompressible fluid. For gases with a pressure drop above a few percent of the line pressure, an expansibility factor is needed.
  • The flow must be fully turbulent and well developed; bends and valves just upstream distort the reading.
  • Because Δp varies with the square of the flow, the meter loses accuracy at low flows.

Frequently asked questions

How does a Venturi meter work?

The pipe narrows smoothly to a throat and then widens again. The fluid speeds up in the throat and its pressure drops, as Bernoulli's equation predicts. Measuring that pressure difference gives the flow rate, with Q = Cd × A₂ × √(2Δp ÷ (ρ(1 − β⁴))).

What is the discharge coefficient?

The ratio of the real flow to the ideal flow, which accounts for friction and the velocity profile. Classical Venturi tubes have a coefficient of about 0.98 to 0.995, according to ISO 5167-4, compared with about 0.6 for a sharp-edged orifice plate.

What is the beta ratio?

The throat diameter divided by the inlet diameter. Standard Venturi tubes use a beta between about 0.3 and 0.75. A smaller beta gives a larger, easier-to-read pressure difference but a higher permanent pressure loss.

Why choose a Venturi over an orifice plate?

The gradual cone after the throat recovers most of the pressure, so the permanent loss is often only 5 to 20% of the measured difference. Venturis also handle dirty fluids better. They are longer and more expensive than orifice plates.