Skip to content
Omnikalc

Water conductivity to TDS calculator: convert EC to dissolved solids at 25 °C

Enter the conductivity and the temperature of a water sample to get the conductivity at 25 °C, the total dissolved solids in mg/L, the dS/m value, the resistivity and a drinking water rating.

Updated on
Your inputs
µS/cm

Value out of range

°C

Value out of range

Results

Total dissolved solids (TDS)

387.0 mg/L

Good drinking water
Conductivity compensated to 25 °C
604.7 µS/cm
Conductivity in dS/m
0.605 dS/m
Resistivity
1.654 kΩ·cm

A conductivity meter does not measure the salt in the water directly: it measures how well the water carries current. The water conductivity to TDS calculator converts the electrical conductivity into total dissolved solids in mg/L, after correcting the reading to 25 °C, and rates the result with the WHO taste scale.

How the calculation works

  • Enter the electrical conductivity that your meter shows, in microsiemens per centimeter (µS/cm), and the temperature of the sample.
  • The calculator corrects the reading to 25 °C, the reference temperature, with the usual coefficient of 2 % per degree.
  • Choose the conversion factor: 0.64 for most natural waters, 0.50 for salty water and 0.70 for hydroponic solutions. TDS = factor × EC₂₅.
  • The result is the TDS in mg/L, a rating on the WHO taste scale, the conductivity in dS/m and the resistivity.

Example

A meter shows 520 µS/cm at 18 °C. At 25 °C the conductivity would be 520 / (1 + 0.02 × (18 − 25)) = 604.7 µS/cm, or 0.605 dS/m. With the factor 0.64, the TDS is 387.0 mg/L, which is a good drinking water on the taste scale. The resistivity is 1.654 kΩ·cm.

Why it matters

The calculator helps aquarium keepers, gardeners, pool owners, brewers and anyone with a TDS pen to read a meter correctly. It is also used for hydroponic nutrient solutions, for checking a water filter or reverse osmosis system and for irrigation water.

Good to know

The TDS value is an estimate: the true amount of dissolved solids needs the evaporation and weighing of a sample, and the factor changes with the kind of ions. Non-ionic matter such as sugar or alcohol is not detected. The 2 % per degree compensation is accurate near 25 °C and less so for very cold or hot water. The calculator rates only the taste and it does not test the safety of water; use a lab test for contaminants.

The water hardness calculator converts hardness units, the pool chlorine calculator doses sanitizer, the hydroponic nutrients calculator helps to prepare feed solutions, and the dilution calculator plans the volumes of a mix.

Frequently asked questions

How is conductivity related to dissolved solids?

Dissolved salts split into ions that carry current, so the conductivity of water grows with the amount of dissolved salt. The relation is close to linear in a given water, and TDS is about 0.5 to 0.7 times the conductivity in µS/cm. The factor depends on the ions: it is 0.5 for sodium chloride solutions, and a little higher for hard waters rich in calcium and bicarbonate.

Why correct the reading to 25 °C?

The conductivity of water rises about 2 % for each degree of temperature, because the ions move faster in a warmer water. A reading of 520 µS/cm at 18 °C and one of 605 µS/cm at 25 °C are the same water. Many meters do this automatically (ATC). If your meter already compensates, enter 25 °C as the temperature to avoid a double correction.

What is a good TDS for drinking water?

The WHO taste scale rates water by TDS: under 300 mg/L is excellent, 300 to 600 good, 600 to 900 fair, 900 to 1200 poor and above 1200 unacceptable. These are about taste and not about safety: a low TDS does not make water safe, and a high TDS from harmless minerals is not dangerous. A US guideline for the secondary standard is 500 mg/L.

What is the unit dS/m?

A decisiemens per meter equals 1000 µS/cm and 1 mS/cm. Agronomists use it for the salinity of irrigation water and soil extracts: crops start to suffer around 1 to 2 dS/m for the most sensitive plants. The resistivity is the inverse, in kΩ·cm; pure water has about 18 MΩ·cm, so the reading of a drinking water is in the kΩ·cm range.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.