Skip to content
Omnikalc

Scuba SAC rate and air consumption calculator

Work out your surface air consumption from a measured part of a dive, then estimate how long your tank lasts at a planned depth before you reach your reserve.

Updated on
Your inputs
psi

Value out of range

min

Value out of range

ft

Value out of range

cu ft

Value out of range

psi

Value out of range

ft

Value out of range

psi

Value out of range

psi

Value out of range

Results

Surface air consumption (SAC)

17.9 psi/min

Bottom time before reaching reserve

47 min

Respiratory minute volume (RMV)
0.46 cu ft/min
0.5 cu ft/min or less: calm, efficient breathing
Consumption at the planned depth
53.7 psi/min
Ambient pressure at the planned depth
3.00 atm

This calculator is for education and dive planning practice. It does not replace training, your agency’s gas planning rules, a dive computer or your buddy check. Always end dives with the reserve you planned.

SAC and RMV

Air consumption rises with depth because each breath at depth holds more gas: at 33 ft of seawater the pressure is 2 atmospheres, at 66 ft 3 atmospheres. To compare dives, divers convert consumption back to the surface:

  • SAC (surface air consumption), in psi per minute: pressure used ÷ minutes ÷ (depth ÷ 33 + 1).
  • RMV (respiratory minute volume), in cubic feet per minute: SAC × tank capacity ÷ rated pressure. RMV does not depend on the tank, so it is the better number to remember.

Example

You used 900 psi in 20 minutes at an average 50 ft on an aluminum 80 (77.4 cu ft at 3,000 psi):

  • SAC = 900 ÷ 20 ÷ 2.52 = 17.9 psi/min
  • RMV = 17.9 × 77.4 ÷ 3,000 = 0.46 cu ft/min

Planning a dive

At a planned 66 ft, ambient pressure is 3 atm, so you use 17.9 × 3 = 53.7 psi/min. Starting at 3,000 psi and keeping 500 psi in reserve leaves 2,500 psi, about 47 minutes. This ignores the ascent, the safety stop, stress and cold, all of which raise consumption. Many divers plan with the rule of thirds (one third out, one third back, one third reserve) or a calculated “rock bottom” reserve for two divers sharing air to the surface.

Typical values

RMV Profile
Under 0.5 cu ft/min Calm, experienced diver
0.5 to 0.8 Typical recreational diver
Over 0.8 New, cold, working hard or stressed

How to measure yours

Note the pressure at the start and end of a steady part of a dive, at a constant depth, and the time spent there. Repeat over several dives and use a conservative (higher) value for planning.

Lowering your consumption

Good buoyancy and trim, slow fin kicks, a well-fitted exposure suit and relaxed, deep breathing all help. Fitness matters too. Never skip breaths to save air; it builds up carbon dioxide.

Frequently asked questions

What is the difference between SAC and RMV?

SAC is surface air consumption in psi per minute and depends on your tank. RMV is the volume you breathe per minute at the surface, in cubic feet, and is the same whatever tank you use.

What is a normal RMV?

Calm, experienced divers often breathe under 0.5 cu ft/min. Typical recreational divers are around 0.5 to 0.8, and cold, current or stress push it higher.

Why does consumption increase with depth?

Each breath at depth holds gas at ambient pressure. At 66 ft the pressure is 3 atmospheres, so the same breath uses three times as much gas as at the surface.

Can I plan dives with this alone?

No. Use it to understand and practice gas planning, then follow your training, agency rules, reserve policy and dive computer, and include ascent and safety stops.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.