The cathodic protection calculator estimates the current demand of a coated steel structure and the mass and number of sacrificial anodes needed to protect it for a chosen design life, with magnesium, zinc or aluminum anodes.
How the calculation works
- Enter the surface area to protect and the current density needed by bare steel in its environment (about 1 mA/ft² in soil, 5 or more in seawater).
- Enter the coating breakdown factor, which is the share of the surface assumed to be bare at the end of life (5% for a good coating).
- Choose the anode material with its current capacity, the utilization factor, the design life and the mass of one anode.
- The calculator finds the current demand I = area × density × breakdown, the total anode mass m = I × hours / (capacity × utilization) and the number of anodes.
Example
A buried tank and pipe have 5,000 ft² of steel, a bare-steel current density of 1 mA/ft² and a coating breakdown factor of 5%. The current demand is 5,000 × 1 × 0.05 = 250 mA, or 0.250 A. For 20 years (175,200 h) with magnesium anodes (279 A·h/lb) at 85% utilization, the anode mass is 0.25 × 175,200 / (279 × 0.85) = 184.7 lb. With 17 lb anodes, this takes 11 anodes, each with a 22.7 mA output.
Why it matters
The calculator helps corrosion engineers, pipeline and tank owners, marine and water utility staff, and students to make a first sizing of a galvanic protection system, to compare anode materials and to see when an impressed current system is better. It is a preliminary design tool and not a substitute for a field survey.
Good to know
Use a current density tested in your soil or water, not a general value. Take a pessimistic coating breakdown for the end of life. Check the anode resistance to ground and the driving voltage. Follow a standard such as NACE SP0169 or ISO 15589 for the final design, and verify the potential with a survey after installation.
Related tools
The corrosion rate calculator gives the loss of metal, the Ohm’s law calculator covers the circuit, the wire resistance calculator covers the cables and the density calculator converts the mass of the anodes.