Cathodic protection calculator: current and anodes for corrosion protection

Enter the surface area, the current density, the coating breakdown, the anode material, the utilization and the design life to get the current demand, the total anode mass, the number of anodes and the output per anode.

Updated on
Your inputs
ft²

Value out of range

mA/ft²

Value out of range

%

Value out of range

%

Value out of range

years

Value out of range

lb

Value out of range

Results

Current demand

0.250 A

Total anode mass required
184.7 lb
Number of anodes
11
Current output per anode
22.7 mA

The cathodic protection calculator estimates the current demand of a coated steel structure and the mass and number of sacrificial anodes needed to protect it for a chosen design life, with magnesium, zinc or aluminum anodes.

How the calculation works

  • Enter the surface area to protect and the current density needed by bare steel in its environment (about 1 mA/ft² in soil, 5 or more in seawater).
  • Enter the coating breakdown factor, which is the share of the surface assumed to be bare at the end of life (5% for a good coating).
  • Choose the anode material with its current capacity, the utilization factor, the design life and the mass of one anode.
  • The calculator finds the current demand I = area × density × breakdown, the total anode mass m = I × hours / (capacity × utilization) and the number of anodes.

Example

A buried tank and pipe have 5,000 ft² of steel, a bare-steel current density of 1 mA/ft² and a coating breakdown factor of 5%. The current demand is 5,000 × 1 × 0.05 = 250 mA, or 0.250 A. For 20 years (175,200 h) with magnesium anodes (279 A·h/lb) at 85% utilization, the anode mass is 0.25 × 175,200 / (279 × 0.85) = 184.7 lb. With 17 lb anodes, this takes 11 anodes, each with a 22.7 mA output.

Why it matters

The calculator helps corrosion engineers, pipeline and tank owners, marine and water utility staff, and students to make a first sizing of a galvanic protection system, to compare anode materials and to see when an impressed current system is better. It is a preliminary design tool and not a substitute for a field survey.

Good to know

Use a current density tested in your soil or water, not a general value. Take a pessimistic coating breakdown for the end of life. Check the anode resistance to ground and the driving voltage. Follow a standard such as NACE SP0169 or ISO 15589 for the final design, and verify the potential with a survey after installation.

The corrosion rate calculator gives the loss of metal, the Ohm’s law calculator covers the circuit, the wire resistance calculator covers the cables and the density calculator converts the mass of the anodes.

Frequently asked questions

How does cathodic protection work?

A buried or immersed steel structure corrodes because anodic areas on its surface lose metal. Cathodic protection makes the whole structure a cathode by supplying a small DC current, either from sacrificial anodes of a more active metal such as magnesium, zinc or aluminum, or from a rectifier and inert anodes. The protective current stops the loss of steel at the expense of the anodes.

What is the coating breakdown factor?

No coating is perfect. The breakdown factor is the share of the surface that is assumed to be bare steel and that needs current. It is 1 to 2% for a good new coating, rises with age, and reaches 10% or more for an old or damaged coating. The current demand is proportional to this factor, so it is the most important design assumption for a coated structure.

Which anode material should I use?

Magnesium has the highest driving voltage and is used in high-resistivity soils. Zinc has a lower driving voltage and is used in low-resistivity soils and in seawater. Aluminum alloys have the best capacity per pound and are common in seawater and marine structures. The capacity values used here are practical values that take efficiency into account, and the supplier’s data for the exact alloy should be used.

When is an impressed current system better?

Sacrificial anodes suit small demands, under a few amperes. For large structures, long pipelines or high-resistivity soils, the mass and the number of anodes become impractical, and a transformer-rectifier with inert anodes is used. The calculator warns when the current demand is high. A design must also check the anode resistance to ground, which limits the output of each anode.

Was this calculator helpful?