Skip to content
Omnikalc

Composite wall sound transmission calculator with a door and a window

Enter the area and the sound transmission loss of the wall, the door and the window, and the target, to get the composite loss, the share of sound through each element and the shortfall.

Updated on
Your inputs
ft²

Value out of range

dB

Value out of range

ft²

Value out of range

dB

Value out of range

ft²

Value out of range

dB

Value out of range

dB

Value out of range

Results

Composite sound transmission loss

36.1 dB

Loss compared with the wall alone
15.9 dB
Sound energy through the door
67.4 %
Sound energy through the window
30.7 %
Sound energy through the wall
2.0 %
Shortfall to the target
8.9 dB
Below the target: improve the weakest element, usually the door or the window

The composite wall sound transmission class calculator gives the composite sound transmission loss of a wall with a door and a window, the loss compared with the wall alone, the share of sound which goes through each element and the shortfall to the target, by area weighting.

How the calculation works

  • Enter the gross area of the wall and its sound transmission loss.
  • Enter the area and the loss of the door and of the window.
  • Enter the target to get the composite loss, the share of sound through each element and the shortfall.

Example

A wall of 200 ft² has a door of 21 ft² at 28 dB and a window of 24 ft² at 32 dB, so the wall itself is 155 ft² at 52 dB. The sound energy transmitted is 155 × 10^-5.2 + 21 × 10^-2.8 + 24 × 10^-3.2, and the composite loss is 36.1 dB, that is 15.9 dB below the wall alone. The door lets 67.4 % of the sound and the window 30.7 %. A target of 45 dB is missed by 8.9 dB.

Why it matters

The calculator helps architects, acoustic consultants, builders and students to see which element controls the insulation of a partition, to decide where to invest in a better door or window, and to check a wall against a target such as the one for a bedroom or an office.

Good to know

Improve the weakest element first, and seal the perimeter of the door and of the window with a continuous gasket. Seal the penetrations of the pipes and the cables with a non-hardening sealant, and avoid back-to-back electrical boxes in a rated wall. Check the work on the site with a field test when the insulation is critical.

The sound insulation calculator gives the mass law and the rating of a single wall, the soundproofing cost calculator estimates the cost of the treatments, the decibel addition calculator adds the levels of several sources and the vibration isolation calculator sizes the mounts of a machine.

Frequently asked questions

What is a composite wall?

A composite wall is a wall made of several elements with different sound insulation, like a wall with a door and a window. The sound goes through each element, and the weaker elements let through much more sound per unit of area than the strong ones. The composite insulation is far below the one of the wall alone, and it is controlled by the weakest element.

How is the composite loss found?

Each element has a transmission coefficient, which is the part of the sound energy that goes through it, equal to 10 to the power of minus the loss in dB divided by 10. The coefficients are averaged with the areas as weights, and the composite loss is minus 10 times the logarithm of this average. A small opening with a poor loss changes the result a lot, as the logarithm is dominated by the largest coefficient.

How can the composite wall be improved?

The best way is to improve the weakest element, because it carries most of the sound energy. A solid door with good seals, a laminated glass or a double window, and the sealing of all the gaps and the penetrations often give more than a heavier wall. It makes no sense to build a very high-performance wall and to put a poor door in it.

What are the limits of the calculator?

The calculator uses single-number losses for the elements and the area weighting, as for a simple partition. It does not take into account the flanking paths, the gaps around the door, the frequency of the sound, the absorption of the receiving room, the weighted STC curve or the field measurement. The real result in a building is always lower than the laboratory rating.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.