The concrete evaporation rate calculator gives the evaporation rate of the surface of fresh concrete with the ACI 305 equation, the water lost per hour and the ratio to the limit of 0.2 lb/ft²/h, to assess the risk of plastic shrinkage cracking in hot, dry or windy weather.
How the calculation works
- Enter the concrete temperature, the air temperature, the relative humidity and the wind speed.
- Enter the exposed area of the pour, to find the quantity of water that the surface loses.
- The calculator finds the evaporation rate with the equation of Menzel and Uchida (ACI 305), the water lost per hour and the ratio to the limit of 0.2 lb/ft²/h.
Example
A slab is placed at a concrete temperature of 85 °F, in air at 90 °F, with a relative humidity of 40 % and a wind of 10 mph. The evaporation rate is (85^2.5 − 0.40 × 90^2.5) × (1 + 0.4 × 10) × 10⁻⁶ = 0.179 lb/ft²/h. On 1,000 ft² of exposed surface, the loss is 179 lb/h of water. The rate is 0.90 times the limit of 0.2 lb/ft²/h, so protection is needed.
Why it matters
The calculator helps concrete contractors, finishers, inspectors and engineers to decide if a pour is at risk in hot or windy weather, to compare the effect of the temperatures, the wind and the humidity and to plan the protection of the slab.
Good to know
Measure the temperatures, the humidity and the wind at the site just before and during the pour. Prepare the windbreaks, the misting and the curing materials in advance, and keep the concrete temperature low. Start the curing as soon as the finishing allows it. Record the readings and the measures taken in the daily log, so that the decision to place or to postpone is documented.
Related tools
The concrete curing calculator plans the curing, the concrete volume calculator gives the volume, the concrete crack width calculator checks the cracks and the pool evaporation calculator shows the water loss of a water surface.