Enter the steel stress, the cover, the bar spacing and the strain gradient factor to get the Gergely-Lutz crack width, a check against the usual limits and the maximum bar spacing of ACI 318.

Updated on
Your inputs
ksi

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

Value out of range

Results

Maximum crack width (Gergely-Lutz)

0.0119 in

Within 0.013 in, the former ACI limit for exterior exposure
Effective concrete area around each bar, A = 2 dc s
24.0 in²
Maximum crack width
0.30 mm
Maximum bar spacing allowed by ACI 318-14
12.92 in
Spare spacing: allowed minus actual
6.92 in
The bar spacing meets the code limit

Cracks in reinforced concrete are expected, but their width must stay small. The concrete crack width calculator applies the Gergely-Lutz equation to estimate the maximum crack width from the steel stress, the cover and the bar spacing, and checks the bar spacing against the ACI 318-14 limit.

How the calculation works

  • Enter the steel stress under service loads, about 60% of the yield strength (36 ksi for Grade 60 steel), the cover to the center of the closest bar, the spacing of the bars and the clear cover.
  • Keep the strain gradient factor β at 1.2 for a beam or 1.35 for a thin slab, or compute it as (h − c) / (d − c) from the depths.
  • The calculator finds the effective area of concrete around each bar, A = 2 dc s, and the crack width w = 0.076 β fs ∛(dc A) in thousandths of an inch, with fs in ksi (Gergely and Lutz, 1968).
  • It also computes the maximum bar spacing of ACI 318-14: s = 15 (40 / fs) − 2.5 cc, but not more than 12 (40 / fs), with fs in ksi.

Example

A beam has a service steel stress of 36 ksi, a cover to the bar center dc = 2 in, a bar spacing of 6 in and a clear cover of 1.5 in, with β = 1.2. The effective area is 2 × 2 × 6 = 24 in². The crack width is 0.076 × 1.2 × 36 × ∛(2 × 24) / 1000 = 0.0119 in (0.30 mm), which is within 0.013 in. The maximum spacing of the code is 15 × 40 / 36 − 2.5 × 1.5 = 12.92 in, so the bars have a spare spacing of 6.92 in.

Why it matters

The calculator helps structural engineers, concrete designers and students to check the crack control of a beam, a slab or a wall, to compare bar arrangements, and to see the effect of a closer bar spacing or a thinner cover. It is especially useful for members exposed to weather or to water.

Good to know

Spread the tension steel on many bars of moderate size, not a few big bars. Keep the steel stress at service loads below about 0.6 fy. Do not take the cover below the durability minimum to reduce the crack width. For water tanks, use the specific code with the strict limit of the crack width.

The cracking moment calculator gives the load at the first crack, the rebar development length calculator checks the anchorage, the stirrup spacing calculator covers shear and the beam deflection calculator checks the stiffness after cracking.

Frequently asked questions

Why does reinforced concrete crack?

Concrete is weak in tension, so it cracks in the tension zone of a beam or a slab at a low load, long before the steel yields. The cracks are expected, and the reinforcement carries the tension across them. The designer does not try to prevent the cracks, but to control their width with many well-spread small bars, so that the steel is protected from corrosion and the appearance is acceptable.

What is the Gergely-Lutz equation?

The Gergely-Lutz equation, from tests in the 1960s, predicts the maximum crack width at the tension face: w = 0.076 β fs ∛(dc A) × 10⁻³ in, with fs in ksi, dc in inches and A in square inches. It shows that the width grows with the steel stress, the cover and the area of concrete per bar, so that many small bars are better than a few large ones.

What are the limits on the crack width?

The old ACI 318-95 limits were 0.016 in (0.41 mm) for interior exposure and 0.013 in (0.33 mm) for exterior exposure. Current ACI 318 no longer limits the width directly, but limits the bar spacing at the tension face to s = 15 (40 / fs) − 2.5 cc, but not more than 12 (40 / fs), in inches. Water-retaining structures and aggressive environments need tighter limits.

What are the limits of this calculator?

The equation is an empirical estimate for the maximum width, and actual widths vary by a factor of two or more. It applies to deformed bars in beams and one-way slabs under static service loads. It does not cover the shrinkage and temperature cracks, the cracks from restrained movements, prestressed members or the long-term effects. Eurocode 2 uses another model, with the crack spacing and the strains.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.