Cracks in reinforced concrete are expected, but their width must stay small. The concrete crack width calculator applies the Gergely-Lutz equation to estimate the maximum crack width from the steel stress, the cover and the bar spacing, and checks the bar spacing against the ACI 318-14 limit.
How the calculation works
- Enter the steel stress under service loads, about 60% of the yield strength (36 ksi for Grade 60 steel), the cover to the center of the closest bar, the spacing of the bars and the clear cover.
- Keep the strain gradient factor β at 1.2 for a beam or 1.35 for a thin slab, or compute it as (h − c) / (d − c) from the depths.
- The calculator finds the effective area of concrete around each bar, A = 2 dc s, and the crack width w = 0.076 β fs ∛(dc A) in thousandths of an inch, with fs in ksi (Gergely and Lutz, 1968).
- It also computes the maximum bar spacing of ACI 318-14: s = 15 (40 / fs) − 2.5 cc, but not more than 12 (40 / fs), with fs in ksi.
Example
A beam has a service steel stress of 36 ksi, a cover to the bar center dc = 2 in, a bar spacing of 6 in and a clear cover of 1.5 in, with β = 1.2. The effective area is 2 × 2 × 6 = 24 in². The crack width is 0.076 × 1.2 × 36 × ∛(2 × 24) / 1000 = 0.0119 in (0.30 mm), which is within 0.013 in. The maximum spacing of the code is 15 × 40 / 36 − 2.5 × 1.5 = 12.92 in, so the bars have a spare spacing of 6.92 in.
Why it matters
The calculator helps structural engineers, concrete designers and students to check the crack control of a beam, a slab or a wall, to compare bar arrangements, and to see the effect of a closer bar spacing or a thinner cover. It is especially useful for members exposed to weather or to water.
Good to know
Spread the tension steel on many bars of moderate size, not a few big bars. Keep the steel stress at service loads below about 0.6 fy. Do not take the cover below the durability minimum to reduce the crack width. For water tanks, use the specific code with the strict limit of the crack width.
Related tools
The cracking moment calculator gives the load at the first crack, the rebar development length calculator checks the anchorage, the stirrup spacing calculator covers shear and the beam deflection calculator checks the stiffness after cracking.