Skip to content
Omnikalc

Cold weather concrete calculator: how long an insulated slab stays warm

Enter the slab thickness, the insulation R-value, the placing temperature, the air temperature and the temperature limit to get the time constant, the heat loss, the cooling rate and the time to the limit.

Updated on
Your inputs
in

Value out of range

°F

Value out of range

°F

Value out of range

°F

Value out of range

Results

Time to fall to the temperature limit

49.2 h

Protection for one to three days: check the strength gain
Thermal time constant of the slab
88.0 h
Initial heat loss
8.75 BTU/h·ft²
Initial cooling rate
0.40 °F/h

The cold weather concrete calculator gives the thermal time constant, the initial heat loss, the initial cooling rate and the time to fall to the temperature limit of a protected concrete slab, from the thickness, the R-value of the cover, the placing temperature and the air temperature.

How the calculation works

  • Enter the thickness of the slab and choose the insulation on the top surface by its R-value.
  • Enter the temperature of the concrete when placed, the air temperature and the temperature limit to keep.
  • The calculator finds the thermal time constant, the initial heat loss, the initial cooling rate and the time before the concrete falls to the limit.

Example

A slab of 8 in has a heat capacity of 8 / 12 × 150 × 0.22 = 22 BTU/ft²·°F. With R-4 on the top, the time constant is 22 × 4 = 88 h. The concrete is placed at 55 °F in air at 20 °F, so the initial heat loss is 35 / 4 = 8.75 BTU/h·ft² and the cooling rate is 8.75 / 22 = 0.40 °F/h. The time to fall to 40 °F is 88 × ln(35 / 20) = 49.2 h.

Why it matters

The calculator helps concrete contractors, site engineers, inspectors and students to choose the insulation of a winter pour, to estimate how long the concrete stays above a safe temperature and to compare the covers before the cold night.

Good to know

Do not place concrete on a frozen subgrade, use warm mixing water, and cover the surface at once after the finishing. Measure the temperature of the concrete and of the air with a recorder, keep the protection in place until the concrete has the strength required, and remove it slowly so that the surface does not suffer a thermal shock. Use a heated enclosure and a heat source with a vent for a very cold night, and never a flame heater without a vent in a closed space.

The concrete curing calculator plans the curing and the strength gain, the mass concrete temperature rise calculator handles the heat of hydration, the concrete evaporation rate calculator handles the hot weather and the heat loss calculator estimates the losses of a building.

Frequently asked questions

Why does cold weather matter for concrete?

The hydration of the cement slows down in the cold, and the concrete that freezes before it has reached a strength of about 500 psi (3.5 MPa) can be damaged for good. The guide ACI 306 asks to keep the concrete above a minimum temperature, often 50 °F (10 °C) for the first days, depending on the section, and to protect it with the insulation or the heating.

What is the thermal time constant?

The thermal time constant is the heat capacity of the slab per unit of area times the thermal resistance of the cover. It is the time in which the temperature difference between the concrete and the air falls by about 63 %. A thicker slab and a better insulation give a longer time constant, which means that the concrete stays warm longer.

How is the time to the limit found?

In the simple model, the concrete cools like a body with a constant heat capacity and a constant resistance to the air, so the difference of temperature with the air decreases exponentially. The time to reach the limit is the time constant times the natural logarithm of the ratio of the initial difference to the final difference. The heat of hydration, which slows the cooling, is not included.

What are the limits of the calculator?

The calculator is a conservative model of a slab that loses heat from the top only, with a uniform temperature. It does not include the heat of hydration, the losses by the edges and the forms, the wind, the frozen subgrade, the thermal mass of the forms, the ground heat or the heating. Use the guide ACI 306 and the maturity method to check the strength gain, and measure the temperature of the concrete on site.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.