The cold weather concrete calculator gives the thermal time constant, the initial heat loss, the initial cooling rate and the time to fall to the temperature limit of a protected concrete slab, from the thickness, the R-value of the cover, the placing temperature and the air temperature.
How the calculation works
- Enter the thickness of the slab and choose the insulation on the top surface by its R-value.
- Enter the temperature of the concrete when placed, the air temperature and the temperature limit to keep.
- The calculator finds the thermal time constant, the initial heat loss, the initial cooling rate and the time before the concrete falls to the limit.
Example
A slab of 8 in has a heat capacity of 8 / 12 × 150 × 0.22 = 22 BTU/ft²·°F. With R-4 on the top, the time constant is 22 × 4 = 88 h. The concrete is placed at 55 °F in air at 20 °F, so the initial heat loss is 35 / 4 = 8.75 BTU/h·ft² and the cooling rate is 8.75 / 22 = 0.40 °F/h. The time to fall to 40 °F is 88 × ln(35 / 20) = 49.2 h.
Why it matters
The calculator helps concrete contractors, site engineers, inspectors and students to choose the insulation of a winter pour, to estimate how long the concrete stays above a safe temperature and to compare the covers before the cold night.
Good to know
Do not place concrete on a frozen subgrade, use warm mixing water, and cover the surface at once after the finishing. Measure the temperature of the concrete and of the air with a recorder, keep the protection in place until the concrete has the strength required, and remove it slowly so that the surface does not suffer a thermal shock. Use a heated enclosure and a heat source with a vent for a very cold night, and never a flame heater without a vent in a closed space.
Related tools
The concrete curing calculator plans the curing and the strength gain, the mass concrete temperature rise calculator handles the heat of hydration, the concrete evaporation rate calculator handles the hot weather and the heat loss calculator estimates the losses of a building.