Skip to content
Omnikalc

Crane mat bearing pressure calculator: size the mats under crane outriggers

Enter the maximum outrigger load, the dynamic factor, the mat size and the allowable bearing pressure of the ground to get the pressure under the mat, the use of the ground capacity and the minimum mat area.

Updated on
Your inputs
kips

Value out of range

Value out of range

ft

Value out of range

ft

Value out of range

psf

Value out of range

Results

Bearing pressure under the mat

2,063 psf

Design load on the mat
66.0 kips
Use of the ground capacity
68.8 %
Comfortable margin on the ground
Minimum mat area
22.0 ft²
Minimum side of a square mat
4.69 ft

A crane puts a very large load on a very small outrigger float. The crane mat bearing pressure calculator gives the pressure under a mat from the outrigger load, the dynamic factor and the mat size, compares it with the allowable ground pressure and gives the minimum mat area.

How the calculation works

  • Enter the maximum outrigger load from the load chart of the crane for the planned lift, and a dynamic factor of 1.1 to 1.25 for the movement and the shock of the lift.
  • Enter the length and the width of the crane mat or the cribbing under the outrigger float.
  • Enter the allowable bearing pressure of the ground, from the soil report or from the site investigation.
  • The calculator gives the bearing pressure under the mat, how much of the ground capacity it uses, and the minimum mat area and the side of a square mat that would be needed.

Example

An outrigger carries a maximum load of 60 kips from the chart, with a dynamic factor of 1.1, so the design load is 66 kips. A mat of 8 ft by 4 ft (32 ft²) gives a bearing pressure of 66,000 / 32 = 2,063 psf. For a ground with an allowable pressure of 3,000 psf, the mat uses 68.8% of the capacity. The minimum area is 66,000 / 3,000 = 22.0 ft², or a square mat of 4.69 ft.

Why it matters

The calculator helps crane operators, riggers, site supervisors and students to size the mats and the cribbing under a crane, to check the ground before a lift and to see how a larger mat reduces the pressure. It makes a part of the lift plan clear.

Good to know

Use the maximum outrigger reaction from the load chart for the real configuration. Check the ground and look for utilities and voids under the mat. Put the mat on a level, compacted surface, and extend the float to the center of the mat. If the ground is soft or in doubt, use a larger mat or ask a geotechnical engineer.

The bearing capacity calculator gives the capacity of the soil, the sling angle calculator covers the rigging, the footing size calculator sizes a footing and the wind load calculator covers the wind on the lift.

Frequently asked questions

Why are mats used under crane outriggers?

The float of an outrigger puts a large load on a small area, which can reach 100 psi or more. Most soils cannot carry that. A timber, steel or composite mat spreads the load over a larger area, so that the pressure on the ground is within the capacity of the soil. Crane accidents are often caused by the ground that fails under an outrigger, and the crane tips over.

Where does the outrigger load come from?

The crane manufacturer’s load chart or the lift planning software gives the maximum outrigger reaction for each configuration, boom length, radius and load. The reaction depends on the weight of the crane, the load and the position of the boom, and it is greatest on the outrigger closest to the load. Use the highest value for the planned lift, and not the average.

How is the allowable pressure of the ground found?

A soil report, a geotechnical engineer or the site investigation gives it. As an approximation, soft clay can carry 1,000 to 2,000 psf, firm clay 3,000 to 4,000 psf, dense sand and gravel 5,000 psf or more, and the fill and the soil near utilities or basements often much less. The ground can be weaker after rain. Never assume the capacity of a fill that is not compacted.

What are the limits of this calculator?

It gives the average pressure under a stiff mat that spreads the load evenly. It does not include the bending of the mat, which must be strong enough for the span between the support points, the stress at the edge, the soil layers below that are weaker, the buried utilities and voids, the slope or the effect of wind and swing. Lift planning must be done by a qualified person according to the crane standard.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.