Skip to content
Omnikalc

Critical distance calculator: how close must you be to hear the direct sound?

Enter the room dimensions, the average absorption and the source position to get the critical distance, the room constant and the reverberation time.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

ft

Value out of range

Value out of range

Results

Critical distance

4.68 ft

Room volume
6,000 ft³
Total surface area
2,200 ft²
Room constant R = S α ÷ (1 − α)
550 ft²
Reverberation time (Sabine)
0.67 s

In a room, you hear the direct sound from a source and the sound reflected by the walls. The critical distance calculator finds the distance at which the two have the same level, from the room size, the average absorption and the position of the source. It also gives the volume, the surface area, the room constant and the reverberation time.

How the calculation works

  • Enter the length, width and height of the room, the average absorption coefficient of its surfaces and the position of the source.
  • The calculator finds the volume and the total surface area, and the room constant R = S α / (1 − α).
  • The critical distance is dc = 0.141 √(Q R), the distance from the source at which the direct sound and the reverberant sound have the same level.
  • It also gives the Sabine reverberation time RT = 0.161 V / (S α).

Example

A room of 30 × 20 × 10 ft has an average absorption of 0.2. Its volume is 6,000 ft³ and its surface is 2,200 ft², so the room constant is 550 ft². For a speaker on a hard floor (Q = 2), the critical distance is 4.7 ft. The reverberation time is 0.67 s. A listener beyond 4.7 ft hears more reverberant sound than direct sound.

Why it matters

The critical distance is a basic design number for lecture halls, classrooms, churches, offices, restaurants and sound systems. It shows how far a listener can be from a speaker or a loudspeaker and still hear clearly, and how much absorption is needed to improve the speech intelligibility.

Good to know

The calculator uses the diffuse-field theory with the Sabine reverberation time and the room constant R = S α / (1 − α). It treats the absorption as the same on all surfaces. Real rooms have different materials, furniture, people and openings, so the average coefficient should be computed from the areas of the surfaces. The directivity values are for broadband sound, and a real loudspeaker varies with frequency.

The reverberation time calculator gives the decay of sound in the room, the sound distance calculator covers the direct field, the sound insulation calculator covers the transmission through walls, and the decibel addition calculator adds sound levels.

Frequently asked questions

What is the critical distance?

It is the distance from a sound source at which the level of the direct sound equals the level of the reverberant sound field of the room. Closer than that, the sound comes mostly straight from the source and falls by 6 dB at each doubling of distance. Farther away, the level stays nearly constant, because the reflections dominate.

Why does it matter for speech and music?

Speech is clear when the listener is within the critical distance, or at least within about three times it for good listening conditions. For a lecture hall, church or classroom with long reverberation, a listener beyond the critical distance loses clarity. Sound systems with directional speakers place the audience closer to the speaker than the critical distance.

How can the critical distance be increased?

By adding absorption (ceiling tiles, curtains, carpet, panels), which increases the room constant, or by using a source with a higher directivity, as with a horn speaker or a line array, which increases Q. A larger absorption of 0.4 instead of 0.2 in the example increases the distance by a factor of 1.6.

What are the limits of the formula?

The formula assumes a diffuse sound field, with a uniform distribution of absorption and a room shape that is not too long or flat. In odd rooms, with strong absorption on one side or coupled spaces, the field is not diffuse and the real distance differs. The Sabine formula also loses accuracy for high absorption, above about 0.3.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.