When a surface boils a liquid at a high rate, there is a limit above which the heat transfer collapses. The critical heat flux calculator finds that limit with Zuber’s equation for water, ethanol or liquid nitrogen at atmospheric pressure, for a chosen gravity. With the area and the heat flux of your heater, it gives the maximum heat and the safety margin.
How the calculation works
- Choose the boiling liquid (water, ethanol or liquid nitrogen at atmospheric pressure), the gravity, the heated area and the heat flux that your heater applies.
- The calculator takes the latent heat, the densities of liquid and vapor and the surface tension of the liquid.
- Zuber’s equation gives the critical heat flux: q = 0.131 h_fg ρv^½ [σ g (ρl − ρv)]^¼.
- It then gives the maximum heat for the area and the share of the critical flux that your heater uses.
Example
Water at 1 atm on Earth has a critical heat flux of 1,106 kW/m², which is 350,800 BTU/h·ft². For a heater of 1 ft², the maximum is 350.8 kBTU/h. A heater applying 100,000 BTU/h·ft² runs at 28.5 % of the critical flux, which is a safe margin. On the Moon, the critical flux of the same water would be only 64 % of its value on Earth.
Why it matters
The critical heat flux sets the upper limit of boiling heat transfer in boilers, nuclear reactors, evaporators, cooling of electronics and cryogenic systems. Knowing it, a designer can choose the area of a heater and keep a safe distance from burnout.
Good to know
Zuber’s equation is for pool boiling of a saturated liquid on a large, clean, flat, horizontal surface at 1 atm, with property values at saturation that are fixed here for three liquids. Flow boiling, subcooling, small heaters, rough or coated surfaces, tubes and other pressures change the CHF, sometimes by a factor of 2 or more. Treat the result as a baseline for a first design.
Related tools
The latent heat calculator covers the energy of vaporization, the Bond number calculator compares gravity with surface tension in the same way, Newton’s law of cooling calculator covers convection, and the LMTD calculator covers heat exchangers.