Fixture unit drain sizing calculator: size a building drain from the plumbing fixtures

Enter the number of fixtures and the slope to get the total drainage fixture units, the minimum building drain size, the capacity of that size and the share of capacity used.

Updated on
Your inputs

Value out of range

Value out of range

Value out of range

Value out of range

Value out of range

Value out of range

Value out of range

Results

Minimum building drain size

3 in

Total drainage fixture units (DFU)
27 DFU
Fixture units the drain can carry at that slope
42 DFU
Share of the drain capacity used
64.3 %
The drain has spare capacity

The fixture unit drain sizing calculator adds the drainage fixture units of the plumbing fixtures of a building and gives the minimum size of the building drain for the slope, with the capacity of the pipe and the share used, according to the International Plumbing Code table.

How the calculation works

  • Enter the number of each fixture in the building: water closets, lavatories, showers, bathtubs, kitchen sinks, dishwashers and clothes washers.
  • Choose the slope of the horizontal building drain, usually 1/4 in per foot.
  • The calculator adds the drainage fixture units (DFU) of the International Plumbing Code: 4 for a water closet, 1 for a lavatory and 2 for the others.
  • It selects the smallest building drain whose capacity at your slope is at least the total, with a minimum of 3 in when there is a water closet.

Example

A house has 3 water closets, 3 lavatories, 2 showers, 1 bathtub, 1 kitchen sink, 1 dishwasher and 1 clothes washer. The total is 3 × 4 + 3 × 1 + 2 × 2 + 2 + 2 + 2 + 2 = 27 DFU. At a slope of 1/4 in per ft, a 2 in drain carries 21 DFU and a 3 in drain carries 42 DFU, so the minimum size is 3 in. It is loaded at 27 / 42 = 64.3% of its capacity.

Why it matters

The calculator helps plumbers, designers, builders and homeowners to estimate the size of the drain of a house, a renovation or an addition, to see what happens when a bathroom is added and to avoid an undersized pipe. It gives the first number before the drawing and the permit.

Good to know

Count all the fixtures that discharge into the drain, including floor drains and the equipment of a laundry or a kitchen, which have their own DFU values in the code. Respect the minimum slope when the pipe is installed. Check the sewer connection too, which often has a minimum size, and the local code, because the values differ in some regions.

The sump pump calculator sizes pumps, the drain slope calculator gives the fall of a drain, the pipe flow velocity calculator checks flows and the septic tank size calculator covers on-site treatment.

Frequently asked questions

What is a drainage fixture unit?

A drainage fixture unit (DFU) is a number that expresses the load that a fixture puts on a drainage system, based on the discharge flow rate, the duration and the frequency of use. A lavatory is 1 DFU, a kitchen sink, shower, bathtub, dishwasher or clothes washer 2 DFU, and a private water closet 4 DFU. Using fixture units, and not flow rates, accounts for the fact that fixtures are rarely used at the same time.

How is the drain size found?

The International Plumbing Code (Table 710.1(1)) and the Uniform Plumbing Code give the maximum DFU that a building drain can carry for each pipe size and slope. At a slope of 1/4 in per foot, the values are 21 DFU for 2 in, 42 for 3 in, 216 for 4 in, 480 for 5 in, 840 for 6 in and 1,600 for 8 in. A steeper slope carries more, and a flatter slope carries less.

Why is the minimum size 3 inches with a toilet?

The plumbing codes require a drain of at least 3 in for a water closet, and a building drain that receives the discharge of a water closet cannot be smaller than the fixture outlet, which is about 3 in. A 2 in drain is allowed only for fixtures that do not include a water closet. The sizes listed here are those of the table, and the local code can add its own limits.

Does this size the branches and the vent?

No. The calculator sizes the horizontal building drain. The branches, the stacks and the vents are sized in the same code with their own tables, and the minimum slope is 1/4 in per foot for pipes of 2.5 in or less and 1/8 in per foot for 3 in or more. The result is a preliminary estimate, and the plumber or designer must follow the local code and get the permit.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.