Skip to content
Omnikalc

Unit heater sizing calculator for a shop, garage or warehouse

Enter the size of the building, the temperatures, the U-values, the air changes and the number of heaters to get the heat loss, the capacity of each unit heater and its airflow.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

ft

Value out of range

°F

Value out of range

°F

Value out of range

Btu/h·ft²·°F

Value out of range

Btu/h·ft²·°F

Value out of range

Value out of range

Value out of range

°F

Value out of range

Value out of range

Results

Heating capacity required

74,989 Btu/h

Loss through the walls
15,840 Btu/h
Loss through the roof
6,600 Btu/h
Loss by air leakage
42,768 Btu/h
Capacity of each heater
37,495 Btu/h
Airflow of each heater
694 cfm

The unit heater sizing calculator gives the heat loss of a shop, a garage or a small warehouse, the heating capacity required, the capacity of each heater and its airflow in cfm, from the size of the building, the temperatures, the U-values, the air changes and the number of heaters.

How the calculation works

  • Enter the length, the width and the eave height of the building, and the indoor and outdoor design temperatures.
  • Enter the U-values of the walls and the roof, the air changes per hour, the number of heaters, their temperature rise and a safety factor.
  • The calculator finds the losses, the capacity required, the capacity of each heater and its airflow.

Example

A shop of 60 ft by 40 ft with an eave height of 18 ft is kept at 60 °F when it is 5 °F outside, a difference of 55 °F. The walls lose 3,600 × 0.08 × 55 = 15,840 Btu/h, the roof loses 2,400 × 0.05 × 55 = 6,600 Btu/h, and one air change per hour costs 0.018 × 43,200 × 1 × 55 = 42,768 Btu/h. With a factor of 1.15 the capacity is 74,989 Btu/h, that is 37,495 Btu/h for each of 2 heaters. At a rise of 50 °F, each heater moves 37,495 / (1.08 × 50) = 694 cfm.

Why it matters

The calculator helps contractors, building owners, facility managers and mechanical designers to choose the size and the number of unit heaters, to see how much of the load comes from the air leakage and from the roof, and to compare the effect of a better insulation or of tighter doors before they buy.

Good to know

Use the outdoor design temperature of the local weather data and not the coldest day on record. Check the fuel input and the efficiency on the nameplate, because the capacity of the load is the output of the heater. Place the units so that the air does not blow on the people or on the stored goods, and keep the clearances to combustibles that the manufacturer asks for. Check the venting and the gas supply with the local code.

The heat loss calculator gives the losses of a house, the baseboard heater size calculator sizes the electric heaters of a room, the air changes calculator gives the air flow of a ventilation rate and the duct size calculator sizes the ducts of a system.

Frequently asked questions

How is a unit heater sized?

A unit heater is sized on the heat that the building loses at the outdoor design temperature. The losses are the conduction through the walls and the roof, which is the area times the U-value times the temperature difference, and the air leakage, which is often the largest part in a shop with big doors. The total is multiplied by a safety factor, then shared between the heaters.

Why is the air leakage so large?

A building with overhead doors, loading doors and a high ceiling exchanges its air many times in a day. The calculator uses 0.018 Btu per cubic foot per degree for the air, so one air change per hour in a large volume can be more than the losses of the envelope. Tighter doors and a vestibule reduce this part.

How many heaters should I use?

Two or more smaller heaters give a more even temperature, keep part of the heat if one unit fails, and can be placed along the walls with the most losses. Place them to blow along the outer walls, and not directly at the people. A single large unit is cheaper but heats the space less evenly.

What are the limits of the calculator?

The calculator does not include the slab on the ground, the glazing and the doors with their own U-values, the solar gains, the process heat, the exhaust fans, the altitude or the efficiency of the fuel. Add these losses to the total before you choose the model, and follow the manufacturer's data and the local code for venting and clearances.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.