This calculator gives estimates for education and planning. It is not investment, tax or legal advice; for decisions about your own situation, talk to a qualified financial professional. Most gas furnaces last 15 to 20 years. When one fails in winter, the decision has to be made fast, so it helps to know the typical price ahead of time. A new high-efficiency furnace also burns less fuel than an old one, which pays back part of the cost over the years. This calculator adds the unit, the installation, the ductwork and venting changes, the permit and a thermostat, then estimates the yearly savings and the payback time.
How the calculation works
- Total cost = furnace + installation labor + ductwork and venting changes + permit + thermostat
- Yearly savings = yearly heating bill × (1 − old efficiency ÷ new efficiency)
- Payback time = total ÷ yearly savings
A $3,500 furnace, $2,000 of installation, $500 of ductwork and venting, a $200 permit and a $200 thermostat cost $6,400. Moving from 80% to 96% efficiency on a $1,200 heating bill saves $200 a year, a payback of 32.0 years on the whole system.
Typical prices
| Item | Typical price |
|---|---|
| 80% AFUE gas furnace, installed | $3,000 to $6,000 |
| 95% to 98% AFUE gas furnace, installed | $4,500 to $9,000 |
| Electric furnace, installed | $2,000 to $5,000 |
| PVC venting for a condensing furnace | $300 to $1,500 |
| Ductwork repair or modification | $500 to $3,000 |
| Smart thermostat | $150 to $300 |
Reading the payback
The payback looks long because the calculator counts the whole price, but you usually have to replace a dead furnace anyway. The fairer comparison is the extra cost of a high-efficiency model over a basic one: if that difference is $1,500, the $200 savings repay it in about 7.5 years. Efficiency matters more in cold climates with large heating bills.
Other options
A heat pump heats and cools, can lower bills further in moderate climates and may qualify for federal tax credits and utility rebates. A dual-fuel system pairs a heat pump with a gas furnace for the coldest days. Whatever you choose, get the system sized with a Manual J load calculation rather than matching the old unit, and ask for at least three quotes including the warranty terms.