Skip to content
Omnikalc

Gasket seating load calculator: bolt load needed to seat and hold a flange gasket

Enter the gasket size, factors m and y, the design pressure and the bolts to get the operating load, the gasket seating load, the governing bolt load, the required bolt area and the margin of the bolting.

Updated on
Your inputs
in

Value out of range

in

Value out of range

Value out of range

psi

Value out of range

psi

Value out of range

Value out of range

in²

Value out of range

psi

Value out of range

Results

Governing bolt load

78,540 lb

Operating load Wm1 (pressure and gasket)
37,699 lb
Gasket seating load Wm2
78,540 lb
Bolt area required
3.142 in²
Bolt area provided
5.028 in²
Bolt area provided over required
1.60
Bolt area is sufficient

The gasket seating load calculator gives the operating load, the gasket seating load, the governing bolt load and the bolt area required for a bolted flange joint, using the ASME Section VIII method with the gasket factors m and y, and compares it with the bolts provided.

How the calculation works

  • Enter the diameter G where the gasket load is reacted (about the mean diameter of the contact) and the contact width N of the gasket.
  • Enter the gasket factor m and the seating stress y of the gasket type (from ASME VIII, Appendix 2 tables), and the design pressure.
  • Enter the number of bolts, the root area of one bolt and the allowable bolt stress.
  • The calculator finds the operating load Wm1 = 0.785 G² P + 2 b π G m P and the seating load Wm2 = π b G y, takes the larger, and compares the bolt area with the area required.

Example

A flange has a gasket with G = 10 in, N = 0.5 in (so b = 0.25 in), m = 3 and y = 10,000 psi at 300 psi. The operating load is 0.785 × 100 × 300 + 2 × 0.25 × π × 10 × 3 × 300 = 37,699 lb. The seating load is π × 0.25 × 10 × 10,000 = 78,540 lb and governs. At 25,000 psi allowable, the area required is 3.142 in². Twelve bolts of 0.419 in² give 5.028 in², or 1.60 times the area required.

Why it matters

The calculator helps mechanical and piping engineers, inspectors, maintenance planners and students to check the bolting of a flange, to compare gasket types and to see whether a change of pressure or gasket needs more bolts. It is a fast first check before a full flange rating.

Good to know

Take m and y from the Code table or from the gasket maker for the exact gasket. Use the root area of the bolts, not the nominal area. Check that the bolt spacing is not too wide for the flange stiffness. Use a controlled tightening method, since friction can change the preload by 30% or more.

The bolt torque calculator gives the tightening torque, the bolt joint stiffness calculator covers the preload, the pressure vessel stress calculator checks the shell and the bolt circle calculator lays out the holes.

Frequently asked questions

What are the gasket factors m and y?

In the ASME Boiler and Pressure Vessel Code, Section VIII, the factor m is the ratio between the residual stress on the gasket and the internal pressure that keeps the joint tight in operation, and y is the minimum stress needed to seat the gasket and make it fill the surface imperfections. Soft gaskets have m of 0.5 to 2 and y of 0 to 3,700 psi, while spiral-wound gaskets have m of 3 and y of 10,000 psi.

Which load governs, Wm1 or Wm2?

Wm1 is the load that the bolts need in operation: it balances the hydrostatic end force on the flange and keeps the gasket compressed. Wm2 is the load needed when the joint is tightened, to seat the gasket at the stress y. The larger of the two sets the bolt area. At low pressure, seating usually governs, and at high pressure the operating condition does.

What is the effective gasket width b?

Only part of the gasket width is effective in sealing. The Code takes the basic width b0 as half of the contact width N, and the effective width b equals b0 when b0 is 0.25 in (6.35 mm) or less, and 0.5 √b0 in inches (2.5 √b0 in millimeters) otherwise. This reduction accounts for the rotation of the flanges, which loads the inner edge of the gasket more than the outer edge.

Is this a complete flange design?

No. It checks only the bolt area against the gasket loads. A full flange design under ASME Section VIII also checks the flange thickness and the moments for the flange stress, the hub, the rigidity and the leakage with the methods of Appendix 2 or of the EN 1591 standard. The target bolt stress during assembly also depends on the tightening method, since friction scatters the preload.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.