Skip to content
Omnikalc

Bolt joint stiffness calculator: how much of the load a bolt really sees

Enter the bolt size, the grip, the materials, the preload and the external load of a bolted joint to get the stiffness of the bolt and the members, the joint constant, the bolt load and stress and the load that separates the joint.

Updated on
Your inputs
in

Value out of range

Value out of range

in

Value out of range

Msi

Value out of range

Msi

Value out of range

lb

Value out of range

lb

Value out of range

ksi

Value out of range

Results

Bolt stress as a share of the proof strength

86.0 %

Below the proof strength
Tensile stress area of the bolt
0.1419 in²
Stiffness of the bolt kb
2,837,970 lb/in
Stiffness of the clamped members km
28,059,434 lb/in
Joint constant C = kb / (kb + km)
0.092
Bolt load Fb = Fi + C P
10,367 lb
Bolt stress
73.1 ksi
Load that separates the joint Fi / (1 − C)
11,011 lb

A bolted joint shares an external load between the bolt and the clamped members, according to their stiffness. The bolt joint stiffness calculator finds the joint constant, the bolt load and stress under the external load, the load that separates the joint and the margin to the proof strength.

How the calculation works

  • Enter the bolt diameter, the threads per inch, the grip length (the total thickness of the clamped members), the moduli of the bolt and of the members, and the preload.
  • Enter the external tensile load per bolt and the proof strength of the bolt (85 ksi for SAE grade 5, 120 ksi for grade 8).
  • The calculator computes the tensile stress area, the stiffness of the bolt kb = As E / L and the stiffness of the members with the 30-degree frustum model: km = 0.5774 π E d / ln[5 (0.5774 L + 0.5 d) / (0.5774 L + 2.5 d)].
  • The joint constant C = kb / (kb + km) is the share of the external load that goes into the bolt. The rest relieves the clamped members.

Example

A 1/2-13 steel bolt (0.5 in, 13 threads per inch) clamps steel plates over a grip of 1.5 in, with a preload of 10,000 lb and an external load of 4,000 lb. The tensile stress area is 0.1419 in². The stiffness of the bolt is 2,837,970 lb/in and the stiffness of the members is 28,059,434 lb/in, so the joint constant is 0.092. The bolt load is 10,000 + 0.092 × 4,000 = 10,367 lb, a stress of 73.1 ksi or 86.0% of an 85 ksi proof strength. The joint separates at 11,011 lb.

Why it matters

The calculator helps mechanical engineers, machine designers, mechanics and students to understand why a bolt does not see the full load, to check a preload against the proof strength, and to predict when a joint opens. It supports the design of flanges, cylinder heads, brackets and any tension joint.

Good to know

Use the actual grip length, with the washers, and the actual material of the members. Keep the bolt load below 90% of the proof strength. Tighten with a method that controls the preload, not only the torque. For cyclic loads, check the fatigue of the bolt with the alternating stress C P / (2 As).

The bolt torque calculator gives the tightening torque for a preload, the bolt shear capacity calculator checks shear joints, the thermal stress calculator covers constrained members and the stress concentration factor calculator covers the threads and holes.

Frequently asked questions

What is the joint constant?

A preloaded bolt and the members it clamps act as two springs in parallel, sharing an external load. The joint constant C = kb / (kb + km) is the fraction of the external load that goes into the bolt. In a typical steel joint, the members are much stiffer than the bolt, so C is small, between 0.1 and 0.25, and most of the external load only reduces the clamping force in the members.

Why does preload improve the fatigue life?

With a high preload, the bolt is already under a high steady tension, and the external load adds only a small fraction C of itself. A fluctuating external load then makes a small alternating stress in the bolt, which is much less than the alternating stress in a loose bolt. This is why a bolt in a cyclic joint is tightened to 75% or more of its proof load.

What is the separation load?

The members stay clamped while the clamping force Fi − (1 − C) P is positive. The joint separates when the external load reaches P = Fi / (1 − C). After separation the bolt carries the whole external load, the preload no longer helps and the fatigue life drops very much. A good design keeps the working load below the separation load with a safety factor.

How accurate is the frustum model?

The 30-degree frustum model of the pressure cone in the members is a common approximation, used in Shigley’s textbook. The real stiffness of the members varies by 20% or more with the shape of the members, the washers and the friction of the faces. The result is good enough for a first design. Use a finite element analysis or tests for a critical joint, as in the VDI 2230 guideline.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.